Skip to main content
Journal cover image

Evaluating the learning curve in the prospective Randomized Clinical Trial of hemodynamic support with Impella 2.5 versus Intra-Aortic Balloon Pump in patients undergoing high-risk percutaneous coronary intervention: a prespecified subanalysis of the PROTECT II study.

Publication ,  Journal Article
Henriques, JPS; Ouweneel, DM; Naidu, SS; Palacios, IF; Popma, J; Ohman, EM; O'Neill, WW
Published in: Am Heart J
April 2014

BACKGROUND: The introduction of new medical devices may be accompanied by a learning curve. METHODS: To evaluate the impact of the device learning curve on the outcomes of PROTECT II trial, comparing Impella 2.5 versus the intra-aortic balloon pump (IABP) during high-risk percutaneous coronary intervention, we report on a prespecified analysis, excluding the first Impella 2.5 and IABP patients at each site. RESULTS: A total of 448 patients were enrolled at 74 sites. Among these, 58 patients were the first to receive Impella 2.5 at their site, 62 were the first to receive IABP. A trend toward higher major adverse events (MAEs) at 30 days was observed for the subgroup of first versus remaining Impella 2.5 patients: 44.8% versus 31.7%, P = .072. MAE rates for the first and remaining IABP patients were similar at 30 days. After exclusion of the first patient in each group, MAE rates for Impella 2.5 and IABP were 31.7% versus 40.0% (P = .119) at 30 days and 38.0% versus 50.0% (P = .029) at 90 days. CONCLUSIONS: Significantly lower 90-day MAE rates were observed with the use of Impella 2.5 compared to the use of IABP after excluding the first patient per group at each site. This prespecified analysis suggests a learning curve associated with initial introduction of the Impella 2.5. Clinical trials should better address the training aspect of new devices, especially when compared with more established devices.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Am Heart J

DOI

EISSN

1097-6744

Publication Date

April 2014

Volume

167

Issue

4

Start / End Page

472 / 479.e5

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Prospective Studies
  • Postoperative Complications
  • Percutaneous Coronary Intervention
  • Male
  • Learning Curve
  • Intra-Aortic Balloon Pumping
  • Humans
  • Hemodynamics
  • Follow-Up Studies
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Henriques, J. P. S., Ouweneel, D. M., Naidu, S. S., Palacios, I. F., Popma, J., Ohman, E. M., & O’Neill, W. W. (2014). Evaluating the learning curve in the prospective Randomized Clinical Trial of hemodynamic support with Impella 2.5 versus Intra-Aortic Balloon Pump in patients undergoing high-risk percutaneous coronary intervention: a prespecified subanalysis of the PROTECT II study. Am Heart J, 167(4), 472-479.e5. https://doi.org/10.1016/j.ahj.2013.12.018
Henriques, José P. S., Dagmar M. Ouweneel, Srihari S. Naidu, Igor F. Palacios, Jeffrey Popma, E Magnus Ohman, and William W. O’Neill. “Evaluating the learning curve in the prospective Randomized Clinical Trial of hemodynamic support with Impella 2.5 versus Intra-Aortic Balloon Pump in patients undergoing high-risk percutaneous coronary intervention: a prespecified subanalysis of the PROTECT II study.Am Heart J 167, no. 4 (April 2014): 472-479.e5. https://doi.org/10.1016/j.ahj.2013.12.018.
Journal cover image

Published In

Am Heart J

DOI

EISSN

1097-6744

Publication Date

April 2014

Volume

167

Issue

4

Start / End Page

472 / 479.e5

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Prospective Studies
  • Postoperative Complications
  • Percutaneous Coronary Intervention
  • Male
  • Learning Curve
  • Intra-Aortic Balloon Pumping
  • Humans
  • Hemodynamics
  • Follow-Up Studies