Predictors of an inadequate defibrillation safety margin at ICD implantation: insights from the National Cardiovascular Data Registry.

Published

Journal Article

BACKGROUND: Defibrillation testing is often performed to establish effective arrhythmia termination, but predictors and consequences of an inadequate defibrillation safety margin (DSM) remain largely unknown. OBJECTIVES: The aims of this study were to develop a simple risk score predictive of an inadequate DSM at implantable cardioverter-defibrillator (ICD) implantation and to examine the association of an inadequate DSM with adverse events. METHODS: A total of 132,477 ICD Registry implantations between 2010 and 2012 were analyzed. Using logistic regression models, factors most predictive of an inadequate DSM (defined as the lowest successful energy tested <10 J from maximal device output) were identified, and the association of an inadequate DSM with adverse events was evaluated. RESULTS: Inadequate DSMs occurred in 12,397 patients (9.4%). A simple risk score composed of 8 easily identifiable variables characterized patients at high and low risk for an inadequate DSM, including (with assigned points) age <70 years (1 point); male sex (1 point); race: black (4 points), Hispanic (2 points), or other (1 point); New York Heart Association functional class III (1 point) or IV (3 points); no ischemic heart disease (2 points); renal dialysis (3 points); secondary prevention indication (1 point); and ICD type: single-chamber (2 points) or biventricular (1 point) device. An inadequate DSM was associated with greater odds of complications (odds ratio: 1.22; 95% confidence interval: 1.09 to 1.37; p = 0.0006), hospital stay >3 days (odds ratio: 1.24; 95% confidence interval: 1.19 to 1.30; p < 0.0001), and in-hospital mortality (odds ratio: 1.96; 95% confidence interval: 1.63 to 2.36; p < 0.0001). CONCLUSIONS: A simple risk score identified ICD recipients at risk for an inadequate DSM. An inadequate DSM was associated with an increased risk for in-hospital adverse events.

Full Text

Duke Authors

Cited Authors

  • Hsu, JC; Marcus, GM; Al-Khatib, SM; Wang, Y; Curtis, JP; Sood, N; Parker, MW; Kluger, J; Lampert, R; Russo, AM

Published Date

  • July 22, 2014

Published In

Volume / Issue

  • 64 / 3

Start / End Page

  • 256 - 264

PubMed ID

  • 25034061

Pubmed Central ID

  • 25034061

Electronic International Standard Serial Number (EISSN)

  • 1558-3597

Digital Object Identifier (DOI)

  • 10.1016/j.jacc.2014.01.085

Language

  • eng

Conference Location

  • United States