Control of simultaneous outbreaks of carbapenemase-producing enterobacteriaceae and extensively drug-resistant Acinetobacter baumannii infection in an intensive care unit using interventions promoted in the Centers for Disease Control and Prevention 2012 carbapenemase-resistant Enterobacteriaceae Toolkit.

Published

Journal Article

OBJECTIVE: We describe the efficacy of enhanced infection control measures, including those recommended in the Centers for Disease Control and Prevention's 2012 carbapenem-resistant Enterobacteriaceae (CRE) toolkit, to control concurrent outbreaks of carbapenemase-producing Enterobacteriaceae (CPE) and extensively drug-resistant Acinetobacter baumannii (XDR-AB). DESIGN: Before-after intervention study. SETTING: Fifteen-bed surgical trauma intensive care unit (ICU). METHODS: We investigated the impact of enhanced infection control measures in response to clusters of CPE and XDR-AB infections in an ICU from April 2009 to March 2010. Polymerase chain reaction was used to detect the presence of blaKPC and resistance plasmids in CRE. Pulsed-field gel electrophoresis was performed to assess XDR-AB clonality. Enhanced infection-control measures were implemented in response to ongoing transmission of CPE and a new outbreak of XDR-AB. Efficacy was evaluated by comparing the incidence rate (IR) of CPE and XDR-AB before and after the implementation of these measures. RESULTS: The IR of CPE for the 12 months before the implementation of enhanced measures was 7.77 cases per 1,000 patient-days, whereas the IR of XDR-AB for the 3 months before implementation was 6.79 cases per 1,000 patient-days. All examined CPE shared endemic blaKPC resistance plasmids, and 6 of the 7 XDR-AB isolates were clonal. Following institution of enhanced infection control measures, the CPE IR decreased to 1.22 cases per 1,000 patient-days (P = .001), and no more cases of XDR-AB were identified. CONCLUSIONS: Use of infection control measures described in the Centers for Disease Control and Prevention's 2012 CRE toolkit was associated with a reduction in the IR of CPE and an interruption in XDR-AB transmission.

Full Text

Duke Authors

Cited Authors

  • Enfield, KB; Huq, NN; Gosseling, MF; Low, DJ; Hazen, KC; Toney, DM; Slitt, G; Zapata, HJ; Cox, HL; Lewis, JD; Kundzins, JR; Mathers, AJ; Sifri, CD

Published Date

  • July 2014

Published In

Volume / Issue

  • 35 / 7

Start / End Page

  • 810 - 817

PubMed ID

  • 24915208

Pubmed Central ID

  • 24915208

Electronic International Standard Serial Number (EISSN)

  • 1559-6834

Digital Object Identifier (DOI)

  • 10.1086/676857

Language

  • eng

Conference Location

  • United States