Stent-assisted coiling versus balloon remodeling of wide-neck aneurysms: comparison of angiographic outcomes.

Journal Article

BACKGROUND AND PURPOSE: Stent-assisted coiling and balloon-assisted coiling are 2 well-established techniques for treatment of wide-neck intracranial aneurysms. A direct comparative analysis of angiographic outcomes with the 2 techniques has not been available. We compare the angiographic outcomes of wide-neck aneurysms treated with stent-assisted coiling versus balloon-assisted coiling. MATERIALS AND METHODS: A retrospective review was conducted on 101 consecutive patients treated at our institution, 69 with stent-assisted coiling and 32 with balloon-assisted coiling. Two multivariate logistic regression analyses were performed to determine predictors of aneurysm obliteration and predictors of progressive aneurysm thrombosis at follow-up. RESULTS: The 2 groups were comparable with respect to all baseline characteristics with the exception of a higher proportion of ruptured aneurysms in the balloon-assisted coiling group (65.6%) than in the stent-assisted coiling group (11.5%, P < .001). Procedural complications did not differ between the stent-assisted coiling group (6%) and the balloon-assisted coiling group (9%, P = .5). The rates of complete aneurysm occlusion (Raymond score 1) at the most recent follow-up were significantly higher for the stent-assisted coiling group (75.4%) compared with the balloon-assisted coiling group (50%, P = .01). Progressive occlusion of incompletely coiled aneurysms was noted in 76.6% of aneurysms in the stent-assisted coiling group versus 42.8% in the balloon-assisted coiling group (P = .02). Retreatment rates were significantly lower with stent-assisted coiling (4.3%) versus balloon-assisted coiling (15.6%, P = .05). In multivariate analysis, stented aneurysms independently predicted both complete aneurysm obliteration and progression of occlusion. CONCLUSIONS: Stent-assisted coiling may yield lower rates of retreatment and higher rates of aneurysm obliteration and progression of occlusion at follow-up than balloon-assisted coiling with a similar morbidity rate.

Full Text

Duke Authors

Cited Authors

  • Chalouhi, N; Starke, RM; Koltz, MT; Jabbour, PM; Tjoumakaris, SI; Dumont, AS; Rosenwasser, RH; Singhal, S; Gonzalez, LF

Published Date

  • October 2013

Published In

Volume / Issue

  • 34 / 10

Start / End Page

  • 1987 - 1992

PubMed ID

  • 23639562

Electronic International Standard Serial Number (EISSN)

  • 1936-959X

International Standard Serial Number (ISSN)

  • 0195-6108

Digital Object Identifier (DOI)

  • 10.3174/ajnr.a3538

Language

  • eng