A comparison of the sensitivities of contrast and isotope voiding cystourethrograms for the detection of pancreas transplant bladder leaks.
Publication
, Journal Article
Rayhill, SC; Odorico, JS; Heisey, DM; Wilson, MA; Pirsch, JD; D'Alessandro, AM; Knechtle, SJ; Belzer, FO; Eckhoff, DE; Sollinger, HW
Published in: Transplant Proc
December 1995
Duke Scholars
Published In
Transplant Proc
ISSN
0041-1345
Publication Date
December 1995
Volume
27
Issue
6
Start / End Page
3143 / 3144
Location
United States
Related Subject Headings
- Urography
- Urinary Bladder
- Technetium Tc 99m Pentetate
- Sensitivity and Specificity
- Radionuclide Imaging
- Pancreas Transplantation
- Kidney Transplantation
- Humans
- False Negative Reactions
- Drainage
Citation
APA
Chicago
ICMJE
MLA
NLM
Rayhill, S. C., Odorico, J. S., Heisey, D. M., Wilson, M. A., Pirsch, J. D., D’Alessandro, A. M., … Sollinger, H. W. (1995). A comparison of the sensitivities of contrast and isotope voiding cystourethrograms for the detection of pancreas transplant bladder leaks. Transplant Proc, 27(6), 3143–3144.
Rayhill, S. C., J. S. Odorico, D. M. Heisey, M. A. Wilson, J. D. Pirsch, A. M. D’Alessandro, S. J. Knechtle, F. O. Belzer, D. E. Eckhoff, and H. W. Sollinger. “A comparison of the sensitivities of contrast and isotope voiding cystourethrograms for the detection of pancreas transplant bladder leaks.” Transplant Proc 27, no. 6 (December 1995): 3143–44.
Rayhill SC, Odorico JS, Heisey DM, Wilson MA, Pirsch JD, D’Alessandro AM, et al. A comparison of the sensitivities of contrast and isotope voiding cystourethrograms for the detection of pancreas transplant bladder leaks. Transplant Proc. 1995 Dec;27(6):3143–4.
Rayhill, S. C., et al. “A comparison of the sensitivities of contrast and isotope voiding cystourethrograms for the detection of pancreas transplant bladder leaks.” Transplant Proc, vol. 27, no. 6, Dec. 1995, pp. 3143–44.
Rayhill SC, Odorico JS, Heisey DM, Wilson MA, Pirsch JD, D’Alessandro AM, Knechtle SJ, Belzer FO, Eckhoff DE, Sollinger HW. A comparison of the sensitivities of contrast and isotope voiding cystourethrograms for the detection of pancreas transplant bladder leaks. Transplant Proc. 1995 Dec;27(6):3143–3144.
Published In
Transplant Proc
ISSN
0041-1345
Publication Date
December 1995
Volume
27
Issue
6
Start / End Page
3143 / 3144
Location
United States
Related Subject Headings
- Urography
- Urinary Bladder
- Technetium Tc 99m Pentetate
- Sensitivity and Specificity
- Radionuclide Imaging
- Pancreas Transplantation
- Kidney Transplantation
- Humans
- False Negative Reactions
- Drainage