Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty.

Publication ,  Journal Article
Marulanda, GA; Ragland, PS; Seyler, TM; Mont, MA
Published in: Surg Technol Int
2005

Fifty primary total knee arthroplasties were performed in a prospective, randomized study comparing the use of a bipolar sealer device versus conventional electrocautery as the method of hemostasis. Both cohorts were evaluated for intraoperative blood loss, transfusion rate, postoperative drainage, hemoglobin levels, and Knee Society scores. A significant reduction in postoperative and total blood loss was found (p = 0.05 and p = 0.02, respectively), as well as an absence of tissue charring and smoke production in the bipolar sealer group. No difference in knee scores was found between both cohorts. These results suggest that use of this bipolar sealing device is at least as effective as standard cautery devices and can reduce blood loss, tissue damage, and smoke production in total knee arthroplasties without affecting the results.

Duke Scholars

Published In

Surg Technol Int

ISSN

1090-3941

Publication Date

2005

Volume

14

Start / End Page

281 / 286

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Prospective Studies
  • Middle Aged
  • Male
  • Humans
  • Hemostasis, Surgical
  • Female
  • Electrocoagulation
  • Blood Loss, Surgical
  • Arthroplasty, Replacement, Knee
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Marulanda, G. A., Ragland, P. S., Seyler, T. M., & Mont, M. A. (2005). Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty. Surg Technol Int, 14, 281–286.
Marulanda, German A., Phillip S. Ragland, Thorsten M. Seyler, and Michael A. Mont. “Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty.Surg Technol Int 14 (2005): 281–86.
Marulanda GA, Ragland PS, Seyler TM, Mont MA. Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty. Surg Technol Int. 2005;14:281–6.
Marulanda, German A., et al. “Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty.Surg Technol Int, vol. 14, 2005, pp. 281–86.
Marulanda GA, Ragland PS, Seyler TM, Mont MA. Reductions in blood loss with use of a bipolar sealer for hemostasis in primary total knee arthroplasty. Surg Technol Int. 2005;14:281–286.

Published In

Surg Technol Int

ISSN

1090-3941

Publication Date

2005

Volume

14

Start / End Page

281 / 286

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Prospective Studies
  • Middle Aged
  • Male
  • Humans
  • Hemostasis, Surgical
  • Female
  • Electrocoagulation
  • Blood Loss, Surgical
  • Arthroplasty, Replacement, Knee