Clinical outcomes in real-world patients with bifurcation lesions receiving Xience V everolimus-eluting stents: Four-year results from the Xience V USA study.

Journal Article

The Xience V USA Study demonstrated safety and efficacy of the XIENCE V(®) everolimus-eluting stent (EES) in a large, prospective study of a real-world, unselected patient population. There is limited long-term data regarding EES performance in high risk patients with bifurcation lesions (BIF). The objective of this analysis was to evaluate the long-term safety and effectiveness of EES in patients with BIF from the XIENCE V USA study.The Xience V USA Study was a single arm, prospective, multicenter, real-world study (n = 5,054) undergoing PCI with EES. Baseline data and clinical outcomes at 4 years were evaluated in the subgroup of patients with ≥ 1 BIF who did not undergo a staged procedure. Co-primary endpoints were ARC definite/probable stent thrombosis and a composite of cardiac death and ARC-defined myocardial infarction (MI). Endpoints were adjudicated by an independent CEC.Of 4,768 patients who did not undergo a staged procedure, there were 511 (10.7%) patients with BIF and 4,257 (89.3%) patients without BIF. Follow-up data was available in 4,459 patients (466 BIF, 3,993 non-BIF). Through binary outcome analysis, at 1 year the overall definite/probable stent thrombosis rates were higher in the BIF group (1.84% vs. 0.76%, P = 0.03). However, at 4 years, the difference in cumulative rates of ARC definite/probable stent thrombosis (BIF 2.3% vs. non-BIF 1.4%, P = 0.13) remained the same as that at 1 year, with no incremental definite/probable stent thrombosis in BIF patients from 2-4 years. The 4-year rates of composite cardiac death and MI were 13.5% for BIF vs. 14.1% for non-BIF (P = 0.78). At 4 years, target lesion failure (19.1% vs. 18.3%, P = 0.66) and ischemia driven-target lesion revascularization (10.2% vs. 10.1%, P = 0.89) were comparable between the two groups.This subgroup analysis of BIF lesions in a real world population receiving EES demonstrates continued low rates of clinical outcomes in the BIF subgroup at 4 years with no incremental stent thrombosis increase in BIF patients from 2 to 4 years. © 2015 Wiley Periodicals, Inc.

Full Text

Duke Authors

Cited Authors

  • Hermiller, JB; Applegate, RJ; Baird, C; Butler, MM; Rutledge, D; Wang, J; Kakarala, K; Krucoff, MW; Sudhir, K

Published Date

  • July 2016

Published In

Volume / Issue

  • 88 / 1

Start / End Page

  • 62 - 70

PubMed ID

  • 26399687

Electronic International Standard Serial Number (EISSN)

  • 1522-726X

International Standard Serial Number (ISSN)

  • 1522-1946

Digital Object Identifier (DOI)

  • 10.1002/ccd.26217