Technological Improvements in Three-Piece Inflatable Penile Prosthesis Design over the Past 40 Years.

Publication ,  Journal Article
Pastuszak, AW; Lentz, AC; Farooq, A; Jones, L; Bella, AJ
Published in: J Sex Med
November 2015

INTRODUCTION: The advent of the penile prosthesis revolutionized the treatment of erectile dysfunction (ED), resulting in near-complete treatment efficacy and high patient satisfaction rates. While several types of penile prosthesis are available, the inflatable penile prosthesis (IPP) is the most commonly used device in the United States. AIMS: To describe the key modifications to IPPs from the two major manufacturers-American Medical Systems (AMS) and Coloplast-since the invention of the IPP, and to relate these changes to improvements in prosthesis function and patient outcomes based on available literature. METHODS: Review and evaluation of the literature between 1973 and present describing modifications in IPP design and the influence of these modifications on IPP durability and patient-related factors. MAIN OUTCOME MEASURES: Data describing the impact of iterative improvements in three-piece IPP design on device function, durability, and patient outcomes. RESULTS: There were progressive improvements in IPP technology from both major manufacturers not only on the durability of the prosthesis but also on patient outcomes, with fewer device failures and lower infection rates. Notable improvements include incorporation of kink-resistant tubing, changes in the weave or addition of shear- and infection-resistant coatings to cylinder layers, pump and tubing connection modifications, the addition of rear tip extenders, and the incorporation of lockout valves to prevent autoinflation. CONCLUSIONS: Numerous incremental modifications to the IPP from both major manufacturers since its invention have increased its durability and improved patient outcomes.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Sex Med

DOI

EISSN

1743-6109

Publication Date

November 2015

Volume

12 Suppl 7

Start / End Page

415 / 421

Location

Netherlands

Related Subject Headings

  • United States
  • Treatment Outcome
  • Prosthesis Implantation
  • Prosthesis Failure
  • Prosthesis Design
  • Penile Prosthesis
  • Patient Satisfaction
  • Obstetrics & Reproductive Medicine
  • Male
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pastuszak, A. W., Lentz, A. C., Farooq, A., Jones, L., & Bella, A. J. (2015). Technological Improvements in Three-Piece Inflatable Penile Prosthesis Design over the Past 40 Years. J Sex Med, 12 Suppl 7, 415–421. https://doi.org/10.1111/jsm.13004
Pastuszak, Alexander W., Aaron C. Lentz, Ahmer Farooq, Leroy Jones, and Anthony J. Bella. “Technological Improvements in Three-Piece Inflatable Penile Prosthesis Design over the Past 40 Years.J Sex Med 12 Suppl 7 (November 2015): 415–21. https://doi.org/10.1111/jsm.13004.
Pastuszak AW, Lentz AC, Farooq A, Jones L, Bella AJ. Technological Improvements in Three-Piece Inflatable Penile Prosthesis Design over the Past 40 Years. J Sex Med. 2015 Nov;12 Suppl 7:415–21.
Pastuszak, Alexander W., et al. “Technological Improvements in Three-Piece Inflatable Penile Prosthesis Design over the Past 40 Years.J Sex Med, vol. 12 Suppl 7, Nov. 2015, pp. 415–21. Pubmed, doi:10.1111/jsm.13004.
Pastuszak AW, Lentz AC, Farooq A, Jones L, Bella AJ. Technological Improvements in Three-Piece Inflatable Penile Prosthesis Design over the Past 40 Years. J Sex Med. 2015 Nov;12 Suppl 7:415–421.
Journal cover image

Published In

J Sex Med

DOI

EISSN

1743-6109

Publication Date

November 2015

Volume

12 Suppl 7

Start / End Page

415 / 421

Location

Netherlands

Related Subject Headings

  • United States
  • Treatment Outcome
  • Prosthesis Implantation
  • Prosthesis Failure
  • Prosthesis Design
  • Penile Prosthesis
  • Patient Satisfaction
  • Obstetrics & Reproductive Medicine
  • Male
  • Humans