Skip to main content
Journal cover image

Laparoscopic secondary port conversion using a reusable blunt conical trocar.

Publication ,  Journal Article
Davis, DR; Schilder, JM; Hurd, WW
Published in: Obstet Gynecol
October 2000

BACKGROUND: During operative laparoscopy, large (10 mm or more) ancillary ports are often used for instrumentation and tissue removal. Although sharp pyramidal trocars can be used to place these ports, their use appears to increase the risk of vessel injury and herniation. We describe a simple and cost-effective technique for converting a 5-mm port to a 10- or 12-mm port using a blunt conical trocar. TECHNIQUE: When a larger port is required, a previously placed 5-mm port is removed, and the skin incision is lengthened. A reusable 10- or 12-mm blunt conical trocar with a threaded sleeve is placed through the incision. The fascial defect is located by probing and is dilated gently with the blunt tip. Once the tip is through the fascia, it is advanced through the peritoneal defect with a clockwise, twisting motion. Afterwards, the fascial defect is closed with a single, interrupted absorbable suture. EXPERIENCE: We have had no complications or difficulty when using this technique in 26 cases, either during or after surgery. CONCLUSION: A reusable blunt conical trocar is a simple, safe, and cost-effective instrument for converting a 5-mm laparoscopic port into a 10- or 12-mm port.

Duke Scholars

Published In

Obstet Gynecol

DOI

ISSN

0029-7844

Publication Date

October 2000

Volume

96

Issue

4

Start / End Page

634 / 635

Location

United States

Related Subject Headings

  • Surgical Instruments
  • Obstetrics & Reproductive Medicine
  • Laparoscopy
  • Humans
  • Gynecologic Surgical Procedures
  • Female
  • 3215 Reproductive medicine
  • 1114 Paediatrics and Reproductive Medicine
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Davis, D. R., Schilder, J. M., & Hurd, W. W. (2000). Laparoscopic secondary port conversion using a reusable blunt conical trocar. Obstet Gynecol, 96(4), 634–635. https://doi.org/10.1016/s0029-7844(99)00268-9
Davis, D. R., J. M. Schilder, and W. W. Hurd. “Laparoscopic secondary port conversion using a reusable blunt conical trocar.Obstet Gynecol 96, no. 4 (October 2000): 634–35. https://doi.org/10.1016/s0029-7844(99)00268-9.
Davis DR, Schilder JM, Hurd WW. Laparoscopic secondary port conversion using a reusable blunt conical trocar. Obstet Gynecol. 2000 Oct;96(4):634–5.
Davis, D. R., et al. “Laparoscopic secondary port conversion using a reusable blunt conical trocar.Obstet Gynecol, vol. 96, no. 4, Oct. 2000, pp. 634–35. Pubmed, doi:10.1016/s0029-7844(99)00268-9.
Davis DR, Schilder JM, Hurd WW. Laparoscopic secondary port conversion using a reusable blunt conical trocar. Obstet Gynecol. 2000 Oct;96(4):634–635.
Journal cover image

Published In

Obstet Gynecol

DOI

ISSN

0029-7844

Publication Date

October 2000

Volume

96

Issue

4

Start / End Page

634 / 635

Location

United States

Related Subject Headings

  • Surgical Instruments
  • Obstetrics & Reproductive Medicine
  • Laparoscopy
  • Humans
  • Gynecologic Surgical Procedures
  • Female
  • 3215 Reproductive medicine
  • 1114 Paediatrics and Reproductive Medicine