Skip to main content
Journal cover image

Performance of phonoelectrocardiographic left ventricular systolic time intervals and B-type natriuretic peptide levels in the diagnosis of left ventricular dysfunction.

Publication ,  Journal Article
Moyers, B; Shapiro, M; Marcus, GM; Gerber, IL; McKeown, BH; Vessey, JC; Jordan, MV; Huddleston, M; Foster, E; Chatterjee, K; Michaels, AD
Published in: Ann Noninvasive Electrocardiol
April 2007

BACKGROUND: Systolic time intervals measured by echocardiography and carotid artery tracings are validated methods of assessing left ventricular function. However, the clinical utility of phonoelectrocardiographic systolic time intervals for predicting heart failure using newer technology has not been evaluated. METHODS: We enrolled 100 adult patients undergoing left heart catheterization. Participants underwent computerized phonoelectrocardiographic analysis, left ventricular end-diastolic pressure (LVEDP) measurement, transthoracic echocardiographic measurement of left ventricular ejection fraction (LVEF), and B-type natriuretic peptide (BNP) testing. The heart rate-adjusted systolic time intervals included the time from the Q wave onset to peak S1 (electromechanical activation time, EMAT), Q wave onset to peak S2 (electromechanical systole, Q-S2), and peak S1 to peak S2 (left ventricular systolic time, LVST). Left ventricular dysfunction was defined as the presence of both LVEDP >15 mmHg and LVEF <50%. RESULTS: EMAT (r =-0.51; P < 0.0001), EMAT/LVST (r =-0.41; P = 0.0001), and Q-S2 (r =-0.39; P = 0.0003) correlated with LVEF, but not with LVEDP. An abnormal EMAT > or =15 (odds ratio 1.38, P < 0.0001) and EMAT/LVST > or =0.40 (OR 1.13, P = 0.002) were associated with left ventricular dysfunction. EMAT > or =15 had 44% sensitivity, 94% specificity, and a 7.0 likelihood ratio for left ventricular dysfunction, while EMAT/LVST > or =0.40 had 55% sensitivity, 95% specificity, and a 11.7 likelihood ratio. In patients with an intermediate BNP (100-500 pg/mL), the likelihood ratio increased from 1.1 using the BNP result alone to 11.0 when adding a positive EMAT test for predicting left ventricular dysfunction. CONCLUSIONS: Phonoelectrocardiographic measures of systolic time intervals are insensitive but highly specific tests for detecting abnormalities in objective markers of left ventricular function. EMAT and EMAT/LVST provide diagnostic information independent of BNP for detecting patients with left ventricular dysfunction.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ann Noninvasive Electrocardiol

DOI

ISSN

1082-720X

Publication Date

April 2007

Volume

12

Issue

2

Start / End Page

89 / 97

Location

United States

Related Subject Headings

  • Ventricular Dysfunction, Left
  • Systole
  • Sensitivity and Specificity
  • ROC Curve
  • Prospective Studies
  • Phonocardiography
  • Natriuretic Peptide, Brain
  • Middle Aged
  • Male
  • Linear Models
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Moyers, B., Shapiro, M., Marcus, G. M., Gerber, I. L., McKeown, B. H., Vessey, J. C., … Michaels, A. D. (2007). Performance of phonoelectrocardiographic left ventricular systolic time intervals and B-type natriuretic peptide levels in the diagnosis of left ventricular dysfunction. Ann Noninvasive Electrocardiol, 12(2), 89–97. https://doi.org/10.1111/j.1542-474X.2007.00146.x
Moyers, Brian, Mia Shapiro, Gregory M. Marcus, Ivor L. Gerber, Barry H. McKeown, Joshua C. Vessey, Mark V. Jordan, et al. “Performance of phonoelectrocardiographic left ventricular systolic time intervals and B-type natriuretic peptide levels in the diagnosis of left ventricular dysfunction.Ann Noninvasive Electrocardiol 12, no. 2 (April 2007): 89–97. https://doi.org/10.1111/j.1542-474X.2007.00146.x.
Moyers B, Shapiro M, Marcus GM, Gerber IL, McKeown BH, Vessey JC, et al. Performance of phonoelectrocardiographic left ventricular systolic time intervals and B-type natriuretic peptide levels in the diagnosis of left ventricular dysfunction. Ann Noninvasive Electrocardiol. 2007 Apr;12(2):89–97.
Moyers, Brian, et al. “Performance of phonoelectrocardiographic left ventricular systolic time intervals and B-type natriuretic peptide levels in the diagnosis of left ventricular dysfunction.Ann Noninvasive Electrocardiol, vol. 12, no. 2, Apr. 2007, pp. 89–97. Pubmed, doi:10.1111/j.1542-474X.2007.00146.x.
Moyers B, Shapiro M, Marcus GM, Gerber IL, McKeown BH, Vessey JC, Jordan MV, Huddleston M, Foster E, Chatterjee K, Michaels AD. Performance of phonoelectrocardiographic left ventricular systolic time intervals and B-type natriuretic peptide levels in the diagnosis of left ventricular dysfunction. Ann Noninvasive Electrocardiol. 2007 Apr;12(2):89–97.
Journal cover image

Published In

Ann Noninvasive Electrocardiol

DOI

ISSN

1082-720X

Publication Date

April 2007

Volume

12

Issue

2

Start / End Page

89 / 97

Location

United States

Related Subject Headings

  • Ventricular Dysfunction, Left
  • Systole
  • Sensitivity and Specificity
  • ROC Curve
  • Prospective Studies
  • Phonocardiography
  • Natriuretic Peptide, Brain
  • Middle Aged
  • Male
  • Linear Models