Skip to main content
Journal cover image

Valve-in-Valve Transcatheter Valve Implantation in the Nonaortic Position.

Publication ,  Journal Article
Ranney, DN; Williams, JB; Wang, A; Gaca, JG
Published in: J Card Surg
May 2016

BACKGROUND: Transcatheter valve-in-valve (VIV) procedures are an alternative to standard surgical valve replacement in high risk patients. METHODS: Cases in which a commercially approved transcatheter aortic valve replacement (TAVR) device was used for a nonaortic VIV procedure between November 2013 and September 2015 are reviewed. Clinical, echocardiographic, and procedural details, patient survival, and symptom severity by NYHA class at follow-up were assessed. RESULTS: All patients were heart-team determined high risk for conventional redo surgery (mean STS PROM = 6.8 ± 2.2%). Five patients underwent VIV replacement in the nonaortic position, four for bioprosthetic mitral valve dysfunction, and one for bioprosthetic tricuspid valve dysfunction. Bioprosthetic failure was due to stenosis in three patients and regurgitation in two others. A balloon-expandable device was used for all patients (Edwards Lifesciences, Irvine, CA, USA). Transcatheter VIV replacement was accomplished by the transapical (mitral) and transfemoral venous (tricuspid) approaches. Median postoperative length of stay was five days (range 3-12). No deaths occurred at a mean follow-up of 21 months. NYHA class at follow-up decreased from class IV at baseline to class I or II for all patients. No paravalvular leaks greater than trivial were encountered. Median mean gradient following mitral replacement was 6.5 mmHg (range 6-13 mmHg), and following tricuspid replacement was 4 mmHg. Postoperative complications included hematuria, epistaxis, acute kidney injury, and atrial fibrillation. CONCLUSIONS: Transcatheter VIV implantation in the nonaortic position for dysfunctional bioprostheses can be performed safely with favorable clinical outcomes using a balloon expandable TAVR device. doi: 10.1111/jocs.12745 (J Card Surg 2016;31:282-288).

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Card Surg

DOI

EISSN

1540-8191

Publication Date

May 2016

Volume

31

Issue

5

Start / End Page

282 / 288

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Time Factors
  • Retrospective Studies
  • Prosthesis Design
  • Postoperative Complications
  • North Carolina
  • Mitral Valve Insufficiency
  • Mitral Valve
  • Male
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ranney, D. N., Williams, J. B., Wang, A., & Gaca, J. G. (2016). Valve-in-Valve Transcatheter Valve Implantation in the Nonaortic Position. J Card Surg, 31(5), 282–288. https://doi.org/10.1111/jocs.12745
Ranney, David N., Judson B. Williams, Andrew Wang, and Jeffrey G. Gaca. “Valve-in-Valve Transcatheter Valve Implantation in the Nonaortic Position.J Card Surg 31, no. 5 (May 2016): 282–88. https://doi.org/10.1111/jocs.12745.
Ranney DN, Williams JB, Wang A, Gaca JG. Valve-in-Valve Transcatheter Valve Implantation in the Nonaortic Position. J Card Surg. 2016 May;31(5):282–8.
Ranney, David N., et al. “Valve-in-Valve Transcatheter Valve Implantation in the Nonaortic Position.J Card Surg, vol. 31, no. 5, May 2016, pp. 282–88. Pubmed, doi:10.1111/jocs.12745.
Ranney DN, Williams JB, Wang A, Gaca JG. Valve-in-Valve Transcatheter Valve Implantation in the Nonaortic Position. J Card Surg. 2016 May;31(5):282–288.
Journal cover image

Published In

J Card Surg

DOI

EISSN

1540-8191

Publication Date

May 2016

Volume

31

Issue

5

Start / End Page

282 / 288

Location

United States

Related Subject Headings

  • Treatment Outcome
  • Time Factors
  • Retrospective Studies
  • Prosthesis Design
  • Postoperative Complications
  • North Carolina
  • Mitral Valve Insufficiency
  • Mitral Valve
  • Male
  • Humans