Reliability of tunnel measurements and the quadrant method using fluoroscopic radiographs after anterior cruciate ligament reconstruction.

Published

Journal Article

BACKGROUND: Anterior cruciate ligament (ACL) reconstruction tunnel placement is often evaluated by radiographs. This study examines the interobserver reliability of various radiographic measurements of ACL tunnels. HYPOTHESIS: When ideal radiographic views are obtained, the interobserver reliability of the measurements among experienced surgeons would be good to excellent. STUDY DESIGN: Descriptive laboratory study. METHODS: Tunnels for single-bundle ACL reconstruction were drilled and filled with metal interference screws or a tibial reamer on 73 cadaveric knees. Ideal fluoroscopic radiographs were obtained. Three independent reviewers performed 18 measurements including a modification of the grid method. For the grid method analysis, reviewers fit a 16 × 12 grid to the lateral knee radiograph, and the center of the femoral tunnel was marked. Interobserver reliability of the measurements was performed using intraclass correlation coefficients (ICCs). A precision grouping analysis was performed for the grid measurements to calculate the mean radius and standard deviation grouping distances. RESULTS: The ICCs were excellent (>.75) for the tibial tunnel angles and tunnel measurements, the clock face measurement, and the Aglietti et al and Jonsson et al measurements. The ICCs were good (.4-.75) for an estimation of graft impingement, Harner et al measurements, and notch height. The mean radius for grid measurements was 0.6 ± 0.4 units (range, 0-2.36 units), with each unit being 1 box in the 16 × 12 grid. When a circle was constructed with a 1.3-unit radius, 95% of the 3 surgeons' measurements would be included in the area of that circle. CONCLUSION: Reliability of ACL tunnel measurements was good to excellent under ideal circumstances for the majority of measurements. The modified grid method demonstrated very acceptable reliability. CLINICAL RELEVANCE: Measurements with good to excellent reliability can be used to evaluate ACL tunnel placement when ideal radiographic views are obtained.

Full Text

Duke Authors

Cited Authors

  • Sullivan, JP; Matava, MJ; Flanigan, DC; Gao, Y; Britton, CL; Amendola, A; MOON Group, ; Wolf, BR

Published Date

  • October 2012

Published In

Volume / Issue

  • 40 / 10

Start / End Page

  • 2236 - 2241

PubMed ID

  • 22962289

Pubmed Central ID

  • 22962289

Electronic International Standard Serial Number (EISSN)

  • 1552-3365

Digital Object Identifier (DOI)

  • 10.1177/0363546512458086

Language

  • eng

Conference Location

  • United States