Coded aperture x-ray diffraction imaging with transmission computed tomography side-information

Published

Conference Paper

© 2016 SPIE. Coded aperture X-ray diffraction (coherent scatter spectral) imaging provides fast and dose-efficient measurements of the molecular structure of an object. The information provided is spatially-dependent and material-specific, and can be utilized in medical applications requiring material discrimination, such as tumor imaging. However, current coded aperture coherent scatter spectral imaging system assume a uniformly or weakly attenuating object, and are plagued by image degradation due to non-uniform self-attenuation. We propose accounting for such non-uniformities in the self-attenuation by utilizing an X-ray computed tomography (CT) image (reconstructed attenuation map). In particular, we present an iterative algorithm for coherent scatter spectral image reconstruction, which incorporates the attenuation map, at different stages, resulting in more accurate coherent scatter spectral images in comparison to their uncorrected counterpart. The algorithm is based on a spectrally grouped edge-preserving regularizer, where the neighborhood edge weights are determined by spatial distances and attenuation values.

Full Text

Duke Authors

Cited Authors

  • Odinaka, I; Greenberg, JA; Kaganovsky, Y; Holmgren, A; Hassan, M; Politte, DG; O'Sullivan, JA; Carin, L; Brady, DJ

Published Date

  • January 1, 2016

Published In

Volume / Issue

  • 9783 /

International Standard Serial Number (ISSN)

  • 1605-7422

International Standard Book Number 13 (ISBN-13)

  • 9781510600188

Digital Object Identifier (DOI)

  • 10.1117/12.2216915

Citation Source

  • Scopus