Trends and In-Hospital Outcomes Associated With Adoption of the Subcutaneous Implantable Cardioverter Defibrillator in the United States.

Published

Journal Article

Importance: Trends and in-hospital outcomes associated with early adoption of the subcutaneous implantable cardioverter defibrillator (S-ICD) in the United States have not been described. Objectives: To describe early use of the S-ICD in the United States and to compare in-hospital outcomes among patients undergoing S-ICD vs transvenous (TV)-ICD implantation. Design, Setting, and Participants: A retrospective analysis of 393 734 ICD implants reported to the National Cardiovascular Data Registry ICD Registry, a nationally representative US ICD registry, between September 28, 2012 (US Food and Drug Administration S-ICD approval date), and March 31, 2015, was conducted. A 1:1:1 propensity-matched analysis of 5760 patients was performed to compare in-hospital outcomes among patients with S-ICD with those of patients with single-chamber (SC)-ICD and dual-chamber (DC)-ICD. Main Outcomes and Measures: Analysis of trends in S-ICD adoption as a function of total ICD implants and comparison of in-hospital outcomes (death, complications, and defibrillation threshold [DFT] testing) among S-ICD and TV-ICD recipients. Results: Of the 393 734 ICD implants evaluated during the study period, 3717 were S-ICDs (0.9%). A total of 109 445 (27.8%) of the patients were female; the mean (SD) age was 67.03 (13.10) years. Use of ICDs increased from 0.2% during the fourth quarter of 2012 to 1.9% during the first quarter of 2015. Compared with SC-ICD and DC-ICD recipients, those with S-ICDs were more often younger, female, black, undergoing dialysis, and had experienced prior cardiac arrest. Among 2791 patients with S-ICD who underwent DFT testing, 2588 (92.7%), 2629 (94.2%), 2635 (94.4%), and 2784 (99.7%) were successfully defibrillated (≤65, ≤70, ≤75, and ≤80 J, respectively). In the propensity-matched analysis of 5760 patients, in-hospital complication rates associated with S-ICDs (0.9%) were comparable to those of SC-ICDs (0.6%) (P = .27) and DC-ICD rates (1.5%) (P = .11). Mean (SD) length of stay after S-ICD implantation was comparable to that after SC-ICD implantation (1.1 [1.5] vs 1.0 [1.2] days; P = .77) and less than after DC-ICD implantation (1.1 [1.5] vs 1.2 [1.5] days; P < .001). Conclusions and Relevance: The use of S-ICDs is rapidly increasing in the United States. Early adoption has been associated with low complication rates and high rates of successful DFT testing despite frequent use in patients with a high number of comorbidities.

Full Text

Duke Authors

Cited Authors

  • Friedman, DJ; Parzynski, CS; Varosy, PD; Prutkin, JM; Patton, KK; Mithani, A; Russo, AM; Curtis, JP; Al-Khatib, SM

Published Date

  • November 1, 2016

Published In

Volume / Issue

  • 1 / 8

Start / End Page

  • 900 - 911

PubMed ID

  • 27603935

Pubmed Central ID

  • 27603935

Electronic International Standard Serial Number (EISSN)

  • 2380-6591

Digital Object Identifier (DOI)

  • 10.1001/jamacardio.2016.2782

Language

  • eng

Conference Location

  • United States