BACKGROUND: The estimation of organ doses and effective doses for children receiving CT examinations is of high interest. Newer, more realistic anthropomorphic body models can provide information on individual organ doses and improved estimates of effective dose. MATERIALS AND METHODS: Previously developed body models representing 50th-percentile individuals at reference ages (newborn, 1, 5, 10 and 15 years) were modified to represent 10th, 25th, 75th and 90th height percentiles for both genders and an expanded range of ages (3, 8 and 13 years). We calculated doses for 80 pediatric reference phantoms from simulated chest-abdomen-pelvis exams on a model of a Philips Brilliance 64 CT scanner. Individual organ and effective doses were normalized to dose-length product (DLP) and fit as a function of body diameter. RESULTS: We calculated organ and effective doses for 80 reference phantoms and plotted them against body diameter. The data were well fit with an exponential function. We found DLP-normalized organ dose to correlate strongly with body diameter (R2>0.95 for most organs). Similarly, we found a very strong correlation with body diameter for DLP-normalized effective dose (R2>0.99). Our results were compared to other studies and we found average agreement of approximately 10%. CONCLUSION: We provide organ and effective doses for a total of 80 reference phantoms representing normal-stature children ranging in age and body size. This information will be valuable in replacing the types of vendor-reported doses available. These data will also permit the recording and tracking of individual patient doses. Moreover, this comprehensive dose database will facilitate patient matching and the ability to predict patient-individualized dose prior to examination.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Pediatr Radiol

DOI

EISSN

1432-1998

Publication Date

May 2017

Volume

47

Issue

6

Start / End Page

691 / 700

Location

Germany

Related Subject Headings

  • Tomography, X-Ray Computed
  • Radiometry
  • Radiation Dosage
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Infant
  • Humans
  • Child, Preschool
  • Child
  • Body Size
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Carver, D. E., Kost, S. D., Fraser, N. D., Segars, W. P., Pickens, D. R., Price, R. R., & Stabin, M. G. (2017). Realistic phantoms to characterize dosimetry in pediatric CT. Pediatr Radiol, 47(6), 691–700. https://doi.org/10.1007/s00247-017-3805-1
Carver, Diana E., Susan D. Kost, Nicholas D. Fraser, W Paul Segars, David R. Pickens, Ronald R. Price, and Michael G. Stabin. “Realistic phantoms to characterize dosimetry in pediatric CT.Pediatr Radiol 47, no. 6 (May 2017): 691–700. https://doi.org/10.1007/s00247-017-3805-1.
Carver DE, Kost SD, Fraser ND, Segars WP, Pickens DR, Price RR, et al. Realistic phantoms to characterize dosimetry in pediatric CT. Pediatr Radiol. 2017 May;47(6):691–700.
Carver, Diana E., et al. “Realistic phantoms to characterize dosimetry in pediatric CT.Pediatr Radiol, vol. 47, no. 6, May 2017, pp. 691–700. Pubmed, doi:10.1007/s00247-017-3805-1.
Carver DE, Kost SD, Fraser ND, Segars WP, Pickens DR, Price RR, Stabin MG. Realistic phantoms to characterize dosimetry in pediatric CT. Pediatr Radiol. 2017 May;47(6):691–700.
Journal cover image

Published In

Pediatr Radiol

DOI

EISSN

1432-1998

Publication Date

May 2017

Volume

47

Issue

6

Start / End Page

691 / 700

Location

Germany

Related Subject Headings

  • Tomography, X-Ray Computed
  • Radiometry
  • Radiation Dosage
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Infant
  • Humans
  • Child, Preschool
  • Child
  • Body Size