Levosimendan in Patients with Left Ventricular Dysfunction Undergoing Cardiac Surgery.

Published

Journal Article

BACKGROUND: Levosimendan is an inotropic agent that has been shown in small studies to prevent or treat the low cardiac output syndrome after cardiac surgery. METHODS: In a multicenter, randomized, placebo-controlled, phase 3 trial, we evaluated the efficacy and safety of levosimendan in patients with a left ventricular ejection fraction of 35% or less who were undergoing cardiac surgery with the use of cardiopulmonary bypass. Patients were randomly assigned to receive either intravenous levosimendan (at a dose of 0.2 μg per kilogram of body weight per minute for 1 hour, followed by a dose of 0.1 μg per kilogram per minute for 23 hours) or placebo, with the infusion started before surgery. The two primary end points were a four-component composite of death through day 30, renal-replacement therapy through day 30, perioperative myocardial infarction through day 5, or use of a mechanical cardiac assist device through day 5; and a two-component composite of death through day 30 or use of a mechanical cardiac assist device through day 5. RESULTS: A total of 882 patients underwent randomization, 849 of whom received levosimendan or placebo and were included in the modified intention-to-treat population. The four-component primary end point occurred in 105 of 428 patients (24.5%) assigned to receive levosimendan and in 103 of 421 (24.5%) assigned to receive placebo (adjusted odds ratio, 1.00; 99% confidence interval [CI], 0.66 to 1.54; P=0.98). The two-component primary end point occurred in 56 patients (13.1%) assigned to receive levosimendan and in 48 (11.4%) assigned to receive placebo (adjusted odds ratio, 1.18; 96% CI, 0.76 to 1.82; P=0.45). The rate of adverse events did not differ significantly between the two groups. CONCLUSIONS: Prophylactic levosimendan did not result in a rate of the short-term composite end point of death, renal-replacement therapy, perioperative myocardial infarction, or use of a mechanical cardiac assist device that was lower than the rate with placebo among patients with a reduced left ventricular ejection fraction who were undergoing cardiac surgery with the use of cardiopulmonary bypass. (Funded by Tenax Therapeutics; LEVO-CTS ClinicalTrials.gov number, NCT02025621 .).

Full Text

Duke Authors

Cited Authors

  • Mehta, RH; Leimberger, JD; van Diepen, S; Meza, J; Wang, A; Jankowich, R; Harrison, RW; Hay, D; Fremes, S; Duncan, A; Soltesz, EG; Luber, J; Park, S; Argenziano, M; Murphy, E; Marcel, R; Kalavrouziotis, D; Nagpal, D; Bozinovski, J; Toller, W; Heringlake, M; Goodman, SG; Levy, JH; Harrington, RA; Anstrom, KJ; Alexander, JH; LEVO-CTS Investigators,

Published Date

  • May 25, 2017

Published In

Volume / Issue

  • 376 / 21

Start / End Page

  • 2032 - 2042

PubMed ID

  • 28316276

Pubmed Central ID

  • 28316276

Electronic International Standard Serial Number (EISSN)

  • 1533-4406

Digital Object Identifier (DOI)

  • 10.1056/NEJMoa1616218

Language

  • eng

Conference Location

  • United States