Skip to main content
Journal cover image

Dynamic confirmation of fixation techniques of the tibial tubercle osteotomy.

Publication ,  Journal Article
Caldwell, PE; Bohlen, BA; Owen, JR; Brown, MH; Harris, B; Wayne, JS; Jiranek, WA
Published in: Clin Orthop Relat Res
July 2004

The tibial tubercle osteotomy is gaining popularity for revision total knee arthroplasty; however, the potential for tubercle displacement has been a concern. This study compared the mechanical behavior of the tibial tubercle osteotomy after screw and cerclage wire fixation. Tibial tubercle osteotomy was done on 40 tibias from cadavers with equal numbers fixed by either screws or wires. Specimens were loaded cyclically to simulate straight leg raises and then loaded to failure with the patellar tendon oriented 0 degrees or 25 degrees from the tibial axis. Tibial tubercle osteotomy cyclic displacement was greater for wire constructs at 25 degrees than all other constructs. Failure loads were greater for screw constructs at 25 degrees than both wire constructs. Screw constructs failed at 1429 +/- 348 N (0 degrees) and at 1925 +/- 982 N (25 degrees). Wire constructs failed at 1072 +/- 260 N (0 degrees) and at 893 +/- 293 N (25 degrees). Bone mineral density correlated positively with failure loads. Straight leg raise (400 N) and knee extension (250 N) against gravity during rehabilitation should be feasible with either screw or wire fixation after tibial tubercle osteotomy. Special care should be taken for the large patient and patients with decreased bone density.

Duke Scholars

Published In

Clin Orthop Relat Res

DOI

ISSN

0009-921X

Publication Date

July 2004

Issue

424

Start / End Page

173 / 179

Location

United States

Related Subject Headings

  • Weight-Bearing
  • Tibia
  • Osteotomy
  • Orthopedics
  • Humans
  • Cadaver
  • Biomechanical Phenomena
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Caldwell, P. E., Bohlen, B. A., Owen, J. R., Brown, M. H., Harris, B., Wayne, J. S., & Jiranek, W. A. (2004). Dynamic confirmation of fixation techniques of the tibial tubercle osteotomy. Clin Orthop Relat Res, (424), 173–179. https://doi.org/10.1097/01.blo.0000130205.57095.a2
Caldwell, Paul E., Barry A. Bohlen, John R. Owen, Michael H. Brown, Barton Harris, Jennifer S. Wayne, and William A. Jiranek. “Dynamic confirmation of fixation techniques of the tibial tubercle osteotomy.Clin Orthop Relat Res, no. 424 (July 2004): 173–79. https://doi.org/10.1097/01.blo.0000130205.57095.a2.
Caldwell PE, Bohlen BA, Owen JR, Brown MH, Harris B, Wayne JS, et al. Dynamic confirmation of fixation techniques of the tibial tubercle osteotomy. Clin Orthop Relat Res. 2004 Jul;(424):173–9.
Caldwell, Paul E., et al. “Dynamic confirmation of fixation techniques of the tibial tubercle osteotomy.Clin Orthop Relat Res, no. 424, July 2004, pp. 173–79. Pubmed, doi:10.1097/01.blo.0000130205.57095.a2.
Caldwell PE, Bohlen BA, Owen JR, Brown MH, Harris B, Wayne JS, Jiranek WA. Dynamic confirmation of fixation techniques of the tibial tubercle osteotomy. Clin Orthop Relat Res. 2004 Jul;(424):173–179.
Journal cover image

Published In

Clin Orthop Relat Res

DOI

ISSN

0009-921X

Publication Date

July 2004

Issue

424

Start / End Page

173 / 179

Location

United States

Related Subject Headings

  • Weight-Bearing
  • Tibia
  • Osteotomy
  • Orthopedics
  • Humans
  • Cadaver
  • Biomechanical Phenomena
  • 3202 Clinical sciences
  • 1103 Clinical Sciences