Skip to main content
Journal cover image

A comparative effectiveness study of eSource used for data capture for a clinical research registry.

Publication ,  Journal Article
Nordo, AH; Eisenstein, EL; Hawley, J; Vadakkeveedu, S; Pressley, M; Pennock, J; Sanderson, I
Published in: Int J Med Inform
July 2017

OBJECTIVE: This pilot study compared eSource-enabled versus traditional manual data transcription (non-eSource methods) for the collection of clinical registry information. The primary study objective was to compare the time spent completing registry forms using eSource versus non-eSource methods The secondary objectives were to compare data quality associated with these two data capture methods and the flexibility of the workflows. This study directly addressed fundamental questions relating to eSource adoption: what time-savings can be realized, and to what extent does eSource improve data quality. MATERIALS AND METHODS: The study used time and motion methods to compare eSource versus non-eSource data capture workflows for a single center OB/GYN registry. Direct observation by industrial engineers using specialized computer software captured keystrokes, mouse clicks and video recordings of the study team in their normal work environment completing real-time data collection. RESULTS: The overall average data capture time was reduced with eSource versus non-eSource methods (difference, 151s per case; eSource, 1603s; non-eSource, 1754s; p=0.051). The average data capture time for the demographic data was reduced (difference, 79s per case; eSource, 133s; non-eSource, 213s; p<0.001). This represents a 37% time reduction (95% confidence interval 27% to 47%). eSourced data field transcription errors were also reduced (eSource, 0%; non-eSource, 9%). CONCLUSION: The use of eSource versus traditional data transcription was associated with a significant reduction in data entry time and data quality errors. Further studies in other settings are needed to validate these results.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Int J Med Inform

DOI

EISSN

1872-8243

Publication Date

July 2017

Volume

103

Start / End Page

89 / 94

Location

Ireland

Related Subject Headings

  • Workflow
  • Software
  • Registries
  • Records
  • Pilot Projects
  • Obstetrics
  • Medical Informatics
  • Humans
  • Gynecology
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Nordo, A. H., Eisenstein, E. L., Hawley, J., Vadakkeveedu, S., Pressley, M., Pennock, J., & Sanderson, I. (2017). A comparative effectiveness study of eSource used for data capture for a clinical research registry. Int J Med Inform, 103, 89–94. https://doi.org/10.1016/j.ijmedinf.2017.04.015
Nordo, Amy Harris, Eric L. Eisenstein, Jeffrey Hawley, Sai Vadakkeveedu, Melissa Pressley, Jennifer Pennock, and Iain Sanderson. “A comparative effectiveness study of eSource used for data capture for a clinical research registry.Int J Med Inform 103 (July 2017): 89–94. https://doi.org/10.1016/j.ijmedinf.2017.04.015.
Nordo AH, Eisenstein EL, Hawley J, Vadakkeveedu S, Pressley M, Pennock J, et al. A comparative effectiveness study of eSource used for data capture for a clinical research registry. Int J Med Inform. 2017 Jul;103:89–94.
Nordo, Amy Harris, et al. “A comparative effectiveness study of eSource used for data capture for a clinical research registry.Int J Med Inform, vol. 103, July 2017, pp. 89–94. Pubmed, doi:10.1016/j.ijmedinf.2017.04.015.
Nordo AH, Eisenstein EL, Hawley J, Vadakkeveedu S, Pressley M, Pennock J, Sanderson I. A comparative effectiveness study of eSource used for data capture for a clinical research registry. Int J Med Inform. 2017 Jul;103:89–94.
Journal cover image

Published In

Int J Med Inform

DOI

EISSN

1872-8243

Publication Date

July 2017

Volume

103

Start / End Page

89 / 94

Location

Ireland

Related Subject Headings

  • Workflow
  • Software
  • Registries
  • Records
  • Pilot Projects
  • Obstetrics
  • Medical Informatics
  • Humans
  • Gynecology
  • Female