Skip to main content

SU‐EE‐A3‐03: A Biomechanical Lung Deformation Model Based On MR Grid‐Tagging Using Hyperpolarized 3He

Publication ,  Conference
Sheng, K; Cai, J; Altes, T; Brookeman, J; Larner, J; Read, P
Published in: Medical Physics
January 1, 2006

Purpose: Deformable image registration is critical for advancements of lung tumor radiation. Commonly used mathematical deformable registrations do not provide actual biomechanical trajectories of anatomical motion. Therefore, we developed a biomechanical registration model (BRM) based on hyperpolarized 3He MRI grid‐tagging to automatically segment structures and generate BRM encoded cine CT images. Method and materials: Normal volunteers underwent hyperpolarized 3He MR imaging on a 1.5T whole‐body MR scanner. Grid‐tagging was achieved by applying sinc‐modulated RF pulses with a composite flip angle of 90° prior to the acquisition of the images followed immediately by a multi‐slice FLASH‐based acquisition at full inspiration and exhalation. For each slice, a displacement vector was computed for each grid element. The complete lung motion was based on spatial and temporal interpolation of the displacement vectors. The motion and deformation of anatomical structures were obtained using the interpolated vector field through various phases. The displacement vectors were registered to a coronal CT image to generate a set BRM encoded cine CT images. Results: Tagging signals were well preserved and sufficient for quantitatively resolving the tag motion. From the displacement vector map, the lower lobes exhibit the greatest motion magnitude especially in the craniocaudal direction. The motion of the structures driven by the displacement map is continuous and smooth. No substantial artifacts in the BRM generated dynamic Ct images were observed. Conclusions and Discussion: BRM provides an independent measure of lung motion and deformation. Compared to pure‐mathematically constructed registrations, BRM relies on fewer assumptions and avoids errors induced by image matching processes. BRM encoded dynamic images are useful to cross‐validate deformable registration by other imaging modalities and algorithms. We plan to explore the potential of this methodology for auto segmentation and treatment planning. © 2006, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2006

Volume

33

Issue

6

Start / End Page

1994

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Sheng, K., Cai, J., Altes, T., Brookeman, J., Larner, J., & Read, P. (2006). SU‐EE‐A3‐03: A Biomechanical Lung Deformation Model Based On MR Grid‐Tagging Using Hyperpolarized 3He. In Medical Physics (Vol. 33, p. 1994). https://doi.org/10.1118/1.2240228
Sheng, K., J. Cai, T. Altes, J. Brookeman, J. Larner, and P. Read. “SU‐EE‐A3‐03: A Biomechanical Lung Deformation Model Based On MR Grid‐Tagging Using Hyperpolarized 3He.” In Medical Physics, 33:1994, 2006. https://doi.org/10.1118/1.2240228.
Sheng K, Cai J, Altes T, Brookeman J, Larner J, Read P. SU‐EE‐A3‐03: A Biomechanical Lung Deformation Model Based On MR Grid‐Tagging Using Hyperpolarized 3He. In: Medical Physics. 2006. p. 1994.
Sheng, K., et al. “SU‐EE‐A3‐03: A Biomechanical Lung Deformation Model Based On MR Grid‐Tagging Using Hyperpolarized 3He.” Medical Physics, vol. 33, no. 6, 2006, p. 1994. Scopus, doi:10.1118/1.2240228.
Sheng K, Cai J, Altes T, Brookeman J, Larner J, Read P. SU‐EE‐A3‐03: A Biomechanical Lung Deformation Model Based On MR Grid‐Tagging Using Hyperpolarized 3He. Medical Physics. 2006. p. 1994.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2006

Volume

33

Issue

6

Start / End Page

1994

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences