Skip to main content
Journal cover image

Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography.

Publication ,  Journal Article
Wong, SS; Vuong, VS; Cunefare, D; Farsiu, S; Moshiri, A; Yiu, G
Published in: American journal of ophthalmology
December 2017

To determine if different types of retinal fluid in the central macula affect the reproducibility of choroidal thickness (CT) measurements on enhanced depth imaging optical coherence tomography (EDI-OCT).Retrospective reliability analysis.EDI-OCT images were obtained and the choroidal-scleral junction was analyzed through semiautomated segmentation. CT was measured at the fovea and averaged across the central 3-mm horizontal segment. Demographic data, central macular thickness, and type of fluid present were recorded. Intragrader and intergrader repeatability were assessed using the intraclass correlation coefficient (ICC) and coefficient of repeatability (CR).Of 124 eyes analyzed, 60 (48.4%) had diabetic macular edema, 32 (25.8%) had neovascular age-related macular degeneration, and 32 (25.8%) had other causes of fluid. Intergrader ICC (CR) was 0.95 (74.1 μm) and 0.96 (63.9 μm) for subfoveal and average CT, respectively. CR was similar across various causes of retinal fluid, but was worst for subretinal fluid compared to intraretinal or sub-retinal pigment epithelial fluid. CR also worsened with increasing choroidal thickness, but was not affected by retinal thickness. Intragrader repeatability was generally greater than intergrader values, and followed the same trend.The presence of macular fluid reduces CT measurement reproducibility, particularly in eyes with subretinal fluid and greater choroidal thickness. A difference of 74.1 μm in subfoveal CT or 63.9 μm in average CT may be necessary to detect true clinical change in eyes with macular fluid.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

American journal of ophthalmology

DOI

EISSN

1879-1891

ISSN

0002-9394

Publication Date

December 2017

Volume

184

Start / End Page

108 / 114

Related Subject Headings

  • Wet Macular Degeneration
  • Tomography, Optical Coherence
  • Subretinal Fluid
  • Retrospective Studies
  • Retinal Pigment Epithelium
  • Reproducibility of Results
  • Ophthalmology & Optometry
  • Male
  • Macula Lutea
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wong, S. S., Vuong, V. S., Cunefare, D., Farsiu, S., Moshiri, A., & Yiu, G. (2017). Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography. American Journal of Ophthalmology, 184, 108–114. https://doi.org/10.1016/j.ajo.2017.10.005
Wong, Sophia S., Vivian S. Vuong, David Cunefare, Sina Farsiu, Ala Moshiri, and Glenn Yiu. “Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography.American Journal of Ophthalmology 184 (December 2017): 108–14. https://doi.org/10.1016/j.ajo.2017.10.005.
Wong SS, Vuong VS, Cunefare D, Farsiu S, Moshiri A, Yiu G. Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography. American journal of ophthalmology. 2017 Dec;184:108–14.
Wong, Sophia S., et al. “Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography.American Journal of Ophthalmology, vol. 184, Dec. 2017, pp. 108–14. Epmc, doi:10.1016/j.ajo.2017.10.005.
Wong SS, Vuong VS, Cunefare D, Farsiu S, Moshiri A, Yiu G. Macular Fluid Reduces Reproducibility of Choroidal Thickness Measurements on Enhanced Depth Optical Coherence Tomography. American journal of ophthalmology. 2017 Dec;184:108–114.
Journal cover image

Published In

American journal of ophthalmology

DOI

EISSN

1879-1891

ISSN

0002-9394

Publication Date

December 2017

Volume

184

Start / End Page

108 / 114

Related Subject Headings

  • Wet Macular Degeneration
  • Tomography, Optical Coherence
  • Subretinal Fluid
  • Retrospective Studies
  • Retinal Pigment Epithelium
  • Reproducibility of Results
  • Ophthalmology & Optometry
  • Male
  • Macula Lutea
  • Humans