Affordable, abbreviated roche monitor assay for quantification of human immunodeficiency virus type 1 RNA in plasma.

Publication ,  Journal Article
Fiscus, SA; Chen, S; Hoover, D; Kerkau, MG; Alabanza, P; Siharath, S; Schmitz, J; Kumwenda, N; Taha, TE
Published in: Journal of clinical microbiology
August 2005

The cost for the Roche Monitor assay kit can be reduced 50% by using only the 1:1, 1:25, and 1:625 human immunodeficiency virus (HIV) and the 1:1 quantitation standard dilutions. This abbreviated test applied to 1,774 mostly African samples had results nearly identical to those obtained following the package insert instructions. To make this approach feasible, Roche would have to provide additional lysis buffer and master mix.

Published In

Journal of clinical microbiology

DOI

EISSN

1098-660X

ISSN

0095-1137

Publication Date

August 2005

Volume

43

Issue

8

Start / End Page

4200 / 4202

Related Subject Headings

  • Viral Load
  • Reagent Kits, Diagnostic
  • RNA, Viral
  • Prospective Studies
  • Pregnancy
  • Microbiology
  • Humans
  • HIV-1
  • Female
  • 3207 Medical microbiology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Fiscus, S. A., Chen, S., Hoover, D., Kerkau, M. G., Alabanza, P., Siharath, S., … Taha, T. E. (2005). Affordable, abbreviated roche monitor assay for quantification of human immunodeficiency virus type 1 RNA in plasma. Journal of Clinical Microbiology, 43(8), 4200–4202. https://doi.org/10.1128/jcm.43.8.4200-4202.2005
Fiscus, Susan A., Shu Chen, Donald Hoover, Melissa G. Kerkau, Paul Alabanza, Som Siharath, John Schmitz, Newton Kumwenda, and Taha E. Taha. “Affordable, abbreviated roche monitor assay for quantification of human immunodeficiency virus type 1 RNA in plasma.Journal of Clinical Microbiology 43, no. 8 (August 2005): 4200–4202. https://doi.org/10.1128/jcm.43.8.4200-4202.2005.
Fiscus SA, Chen S, Hoover D, Kerkau MG, Alabanza P, Siharath S, et al. Affordable, abbreviated roche monitor assay for quantification of human immunodeficiency virus type 1 RNA in plasma. Journal of clinical microbiology. 2005 Aug;43(8):4200–2.
Fiscus, Susan A., et al. “Affordable, abbreviated roche monitor assay for quantification of human immunodeficiency virus type 1 RNA in plasma.Journal of Clinical Microbiology, vol. 43, no. 8, Aug. 2005, pp. 4200–02. Epmc, doi:10.1128/jcm.43.8.4200-4202.2005.
Fiscus SA, Chen S, Hoover D, Kerkau MG, Alabanza P, Siharath S, Schmitz J, Kumwenda N, Taha TE. Affordable, abbreviated roche monitor assay for quantification of human immunodeficiency virus type 1 RNA in plasma. Journal of clinical microbiology. 2005 Aug;43(8):4200–4202.

Published In

Journal of clinical microbiology

DOI

EISSN

1098-660X

ISSN

0095-1137

Publication Date

August 2005

Volume

43

Issue

8

Start / End Page

4200 / 4202

Related Subject Headings

  • Viral Load
  • Reagent Kits, Diagnostic
  • RNA, Viral
  • Prospective Studies
  • Pregnancy
  • Microbiology
  • Humans
  • HIV-1
  • Female
  • 3207 Medical microbiology