Skip to main content
Journal cover image

Potential pitfalls from variable optical coherence tomograph displays in managing diabetic macular edema.

Publication ,  Journal Article
Browning, DJ
Published in: American journal of ophthalmology
September 2003

To describe potential pitfalls in the use of optical coherence tomography for management of diabetic macular edema.Prospective, noninterventional case series.Review of optical coherence tomographs in 13 eyes with clinically significant diabetic macular edema from 11 consecutive patients in a private retina practice.Optical coherence tomography displays are based on 3.5-mm or 6-mm diameter circular grids that look very similar and have identical sector names but schematize different areas of the macula. The numeric outputs for the identically named sectors in the two displays do not differ significantly for retinal thickness but differ significantly in all sectors except the fovea for retinal volume because of the different areas represented by the sectors.Failure to explicitly note the scale of the optical coherence tomography display can potentially misdirect planned focal and grid laser treatment for diabetic macular edema. Failure to explicitly verify identical optical coherence tomography display scales in longitudinal studies of laser treatment for diabetic macular edema can potentially lead to errors in interpreting treatment efficacy.

Published In

American journal of ophthalmology

DOI

EISSN

1879-1891

ISSN

0002-9394

Publication Date

September 2003

Volume

136

Issue

3

Start / End Page

555 / 557

Related Subject Headings

  • Tomography
  • Retina
  • Prospective Studies
  • Ophthalmology & Optometry
  • Macular Edema
  • Light
  • Laser Therapy
  • Interferometry
  • Humans
  • Diagnostic Techniques, Ophthalmological
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Browning, D. J. (2003). Potential pitfalls from variable optical coherence tomograph displays in managing diabetic macular edema. American Journal of Ophthalmology, 136(3), 555–557. https://doi.org/10.1016/s0002-9394(03)00387-8
Browning, David J. “Potential pitfalls from variable optical coherence tomograph displays in managing diabetic macular edema.American Journal of Ophthalmology 136, no. 3 (September 2003): 555–57. https://doi.org/10.1016/s0002-9394(03)00387-8.
Browning DJ. Potential pitfalls from variable optical coherence tomograph displays in managing diabetic macular edema. American journal of ophthalmology. 2003 Sep;136(3):555–7.
Browning, David J. “Potential pitfalls from variable optical coherence tomograph displays in managing diabetic macular edema.American Journal of Ophthalmology, vol. 136, no. 3, Sept. 2003, pp. 555–57. Epmc, doi:10.1016/s0002-9394(03)00387-8.
Browning DJ. Potential pitfalls from variable optical coherence tomograph displays in managing diabetic macular edema. American journal of ophthalmology. 2003 Sep;136(3):555–557.
Journal cover image

Published In

American journal of ophthalmology

DOI

EISSN

1879-1891

ISSN

0002-9394

Publication Date

September 2003

Volume

136

Issue

3

Start / End Page

555 / 557

Related Subject Headings

  • Tomography
  • Retina
  • Prospective Studies
  • Ophthalmology & Optometry
  • Macular Edema
  • Light
  • Laser Therapy
  • Interferometry
  • Humans
  • Diagnostic Techniques, Ophthalmological