Transthoracic impedance compared to magnetic resonance imaging in the assessment of cardiac output.

Published

Journal Article

BACKGROUND: Cardiac magnetic resonance imaging is considered the gold-standard method for the calculation of cardiac volumes. Transthoracic impedance cardiography assesses the cardiac output. No studies validating this measurement, in comparison to that obtained by magnetic resonance imaging, are available. OBJECTIVE: To evaluate the performance of transthoracic impedance cardiography in the calculation of the cardiac output, cardiac index and stroke volume using magnetic resonance imaging as the gold-standard. METHODS: 31 patients with a mean age of 56.7 ± 18 years were assessed; of these, 18 (58%) were males. Patients whose indication for magnetic resonance imaging required pharmacologic stress test were excluded. Correlation between methods was assessed using the Pearson's coefficient, and dispersion of absolute differences in relation to the mean was demonstrated using the Bland-Altman's method. Agreement between methods was analyzed using the intraclass correlation coefficient. RESULTS: The mean cardiac output by transthoracic impedance cardiography and by magnetic resonance imaging was 5.16 ± 0.9 and 5.13 ± 0.9 L/min, respectively. Good agreement between methods was observed for cardiac output (r = 0.79; p = 0.0001), cardiac index (r = 0.74; p = 0.0001) and stroke volume (r = 0.88; p = 0.0001). The analysis by the Bland-Altman plot showed low dispersion of differences in relation to the mean, with a low amplitude of agreement intervals. Good agreement between the two methods was observed when analyzed by the intraclass correlation coefficient, with coefficients for cardiac output, cardiac index and stroke volume of 0.78, 0.73 and 0.88, respectively (p < 0.0001 for all comparisons). CONCLUSION: Transthoracic impedance cardiography proved accurate in the calculation of the cardiac output in comparison to cardiac magnetic resonance imaging.

Full Text

Duke Authors

Cited Authors

  • Villacorta Junior, H; Villacorta, AS; Amador, F; Hadlich, M; Albuquerque, DCD; Azevedo, CF

Published Date

  • December 2012

Published In

Volume / Issue

  • 99 / 6

Start / End Page

  • 1149 - 1155

PubMed ID

  • 23152290

Pubmed Central ID

  • 23152290

Electronic International Standard Serial Number (EISSN)

  • 1678-4170

Digital Object Identifier (DOI)

  • 10.1590/s0066-782x2012005000104

Language

  • eng por

Conference Location

  • Brazil