Evaluating a Portable, Noncontact Fundus Camera for Retinopathy of Prematurity Screening by Nonophthalmologist Health Care Workers.

Publication ,  Journal Article
Prakalapakorn, SG; Freedman, SF; Hutchinson, AK; Wallace, DK; Stinnett, SS; Riggins, JW; Gallaher, KJ
Published in: Ophthalmol Retina
August 2018

PURPOSE: To evaluate (1) the feasibility of non-ophthalmologist healthcare workers (HCWs) to obtain images of sufficient quality for retinopathy of prematurity (ROP) screening using a FDA-approved portable, non-contact, narrow-field fundus camera (i.e., Pictor™), and (2) the accuracy of grading these images to identify infants who developed treatment-warranted (type 1) ROP. DESIGN: Prospective cohort study. SUBJECTS: Infants undergoing routine ROP screening examinations (i.e. birth weight ≤1500 grams and/or gestational age ≤30 weeks or selected infants with a birth weight of 1500-2000g or gestational age >30 weeks and an unstable clinical course). METHODS: We prospectively recruited infants undergoing ROP screening examinations at a community hospital. On the same day an ophthalmologist examined them, a trained HCW imaged their retinas using the non-contact camera. Two masked ROP experts graded these images remotely. We calculated both the percentage of gradable images (i.e. having at least 3 quadrants with sufficient image quality), as well as the accuracy of identifying infants who developed type 1 ROP. MAIN OUTCOME MEASURES: Percentage of gradable images and the sensitivity and specificity of each grader for identifying infants with type 1 ROP by grading for the presence of pre-plus or plus disease. RESULTS: Ninety-nine infants were included. Overall, 92.4% and 94.2% of all infant imaging sessions were considered gradable by graders 1 and 2, respectively. Amongst gradable images, the sensitivity of both graders for identifying type 1 ROP by grading for the presence of pre-plus or plus disease was 100% (95% confidence interval (CI): 95-100%) and the specificity 91% (95% CI: 83-95%) for grader 1 and 93% (95% CI: 86-96%) for grader 2. CONCLUSIONS: It was highly feasible for trained HCWs to obtain digital retinal images of sufficient quality for ROP screening using a non-contact fundus camera. By grading for the presence of pre-plus or plus disease, graders identified infants who developed type 1 ROP with high sensitivity and specificity. The use of portable, non-contact retinal cameras by trained HCWs could increase our workforce in ROP screening and identify infants needing an indirect ophthalmoscopy examination by an ophthalmologist.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Ophthalmol Retina

DOI

ISSN

2468-7219

Publication Date

August 2018

Volume

2

Issue

8

Start / End Page

864 / 871

Location

United States
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Prakalapakorn, S. G., Freedman, S. F., Hutchinson, A. K., Wallace, D. K., Stinnett, S. S., Riggins, J. W., & Gallaher, K. J. (2018). Evaluating a Portable, Noncontact Fundus Camera for Retinopathy of Prematurity Screening by Nonophthalmologist Health Care Workers. Ophthalmol Retina, 2(8), 864–871. https://doi.org/10.1016/j.oret.2017.12.003
Prakalapakorn, S Grace, Sharon F. Freedman, Amy K. Hutchinson, David K. Wallace, Sandra S. Stinnett, J Wayne Riggins, and Keith J. Gallaher. “Evaluating a Portable, Noncontact Fundus Camera for Retinopathy of Prematurity Screening by Nonophthalmologist Health Care Workers.Ophthalmol Retina 2, no. 8 (August 2018): 864–71. https://doi.org/10.1016/j.oret.2017.12.003.
Prakalapakorn SG, Freedman SF, Hutchinson AK, Wallace DK, Stinnett SS, Riggins JW, et al. Evaluating a Portable, Noncontact Fundus Camera for Retinopathy of Prematurity Screening by Nonophthalmologist Health Care Workers. Ophthalmol Retina. 2018 Aug;2(8):864–71.
Prakalapakorn, S. Grace, et al. “Evaluating a Portable, Noncontact Fundus Camera for Retinopathy of Prematurity Screening by Nonophthalmologist Health Care Workers.Ophthalmol Retina, vol. 2, no. 8, Aug. 2018, pp. 864–71. Pubmed, doi:10.1016/j.oret.2017.12.003.
Prakalapakorn SG, Freedman SF, Hutchinson AK, Wallace DK, Stinnett SS, Riggins JW, Gallaher KJ. Evaluating a Portable, Noncontact Fundus Camera for Retinopathy of Prematurity Screening by Nonophthalmologist Health Care Workers. Ophthalmol Retina. 2018 Aug;2(8):864–871.

Published In

Ophthalmol Retina

DOI

ISSN

2468-7219

Publication Date

August 2018

Volume

2

Issue

8

Start / End Page

864 / 871

Location

United States