Purpose To evaluate factors contributing to interreader variation (IRV) in parameters measured at dynamic contrast material-enhanced (DCE) MRI in patients with glioblastoma who were participating in a multicenter trial. Materials and Methods A total of 18 patients (mean age, 57 years ± 13 [standard deviation]; 10 men) who volunteered for the advanced imaging arm of ACRIN 6677, a substudy of the RTOG 0625 clinical trial for recurrent glioblastoma treatment, underwent analyzable DCE MRI at one of four centers. The 78 imaging studies were analyzed centrally to derive the volume transfer constant (Ktrans) for gadolinium between blood plasma and tissue extravascular extracellular space, fractional volume of the extracellular extravascular space (ve), and initial area under the gadolinium concentration curve (IAUGC). Two independently trained teams consisting of a neuroradiologist and a technologist segmented the enhancing tumor on three-dimensional spoiled gradient-recalled acquisition in the steady-state images. Mean and median parameter values in the enhancing tumor were extracted after registering segmentations to parameter maps. The effect of imaging time relative to treatment, map quality, imager magnet and sequence, average tumor volume, and reader variability in tumor volume on IRV was studied by using intraclass correlation coefficients (ICCs) and linear mixed models. Results Mean interreader variations (± standard deviation) (difference as a percentage of the mean) for mean and median IAUGC, mean and median Ktrans, and median ve were 18% ± 24, 17% ± 23, 27% ± 34, 16% ± 27, and 27% ± 34, respectively. ICCs for these metrics ranged from 0.90 to 1.0 for baseline and from 0.48 to 0.76 for posttreatment examinations. Variability in reader-derived tumor volume was significantly related to IRV for all parameters. Conclusion Differences in reader tumor segmentations are a significant source of interreader variation for all dynamic contrast-enhanced MRI parameters. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Wolf in this issue.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Radiology

DOI

EISSN

1527-1315

Publication Date

February 2019

Volume

290

Issue

2

Start / End Page

467 / 476

Location

United States

Related Subject Headings

  • Young Adult
  • Radiologists
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Neoplasm Recurrence, Local
  • Middle Aged
  • Male
  • Magnetic Resonance Imaging
  • Humans
  • Glioblastoma
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Barboriak, D. P., Zhang, Z., Desai, P., Snyder, B. S., Safriel, Y., McKinstry, R. C., … Boxerman, J. L. (2019). Interreader Variability of Dynamic Contrast-enhanced MRI of Recurrent Glioblastoma: The Multicenter ACRIN 6677/RTOG 0625 Study. Radiology, 290(2), 467–476. https://doi.org/10.1148/radiol.2019181296
Barboriak, Daniel P., Zheng Zhang, Pratikkumar Desai, Bradley S. Snyder, Yair Safriel, Robert C. McKinstry, Felix Bokstein, Gregory Sorensen, Mark R. Gilbert, and Jerrold L. Boxerman. “Interreader Variability of Dynamic Contrast-enhanced MRI of Recurrent Glioblastoma: The Multicenter ACRIN 6677/RTOG 0625 Study.Radiology 290, no. 2 (February 2019): 467–76. https://doi.org/10.1148/radiol.2019181296.
Barboriak DP, Zhang Z, Desai P, Snyder BS, Safriel Y, McKinstry RC, et al. Interreader Variability of Dynamic Contrast-enhanced MRI of Recurrent Glioblastoma: The Multicenter ACRIN 6677/RTOG 0625 Study. Radiology. 2019 Feb;290(2):467–76.
Barboriak, Daniel P., et al. “Interreader Variability of Dynamic Contrast-enhanced MRI of Recurrent Glioblastoma: The Multicenter ACRIN 6677/RTOG 0625 Study.Radiology, vol. 290, no. 2, Feb. 2019, pp. 467–76. Pubmed, doi:10.1148/radiol.2019181296.
Barboriak DP, Zhang Z, Desai P, Snyder BS, Safriel Y, McKinstry RC, Bokstein F, Sorensen G, Gilbert MR, Boxerman JL. Interreader Variability of Dynamic Contrast-enhanced MRI of Recurrent Glioblastoma: The Multicenter ACRIN 6677/RTOG 0625 Study. Radiology. 2019 Feb;290(2):467–476.

Published In

Radiology

DOI

EISSN

1527-1315

Publication Date

February 2019

Volume

290

Issue

2

Start / End Page

467 / 476

Location

United States

Related Subject Headings

  • Young Adult
  • Radiologists
  • Observer Variation
  • Nuclear Medicine & Medical Imaging
  • Neoplasm Recurrence, Local
  • Middle Aged
  • Male
  • Magnetic Resonance Imaging
  • Humans
  • Glioblastoma