Skip to main content

TH‐E‐211‐06: Further Development of VirtualDose Software for CT Dose Assessment: Realistic Phantoms and Smartphone User Interfaces

Publication ,  Conference
Ding, A; Schulte, N; Caracappa, P; xu, X
Published in: Medical Physics
January 1, 2011

Purpose: To demonstrate the feasibility of a new software applications for both PC and smartphone users to easily track patient CT doses. Methods: Many of existing tools for reporting CT dose are based on data derived from stylistic phantoms. Based on extensive original dose data derived from Monte Carlo simulations and computational phantoms including a new set of BMI‐adjustable obese patient phantoms, VirtualDose is being designed with interactive, user‐friendly graphical interfaces afforded both on the PC and the smartphone platforms. Organ doses and effective doses are computed using ICRP Publication 60 and 103. The software is developed using the C# for PCs and JAVA for the Android smartphones. Results: VirtualDose offers a modern graphical user interface (GUI) designed to allow interactive 3D phantom display and user‐selectable scanning parameters. Standard scanning ranges can be selected from a pull‐down menu or manually specified on the displayed phantom. The new developed morbidly obese phantom was found to have CT organ doses on average a factor of 0.76 times smaller than that of the normal weight phantom for the same tube current because of shielding by the extra fat. For the same injected activity, the average PET organ dose ratios were 0.95 and 0.65 for source organs and organs in the remainder, respectively. Conclusions: The preliminary GUI design and reporting features of VirtualDose improve upon existing tools by considering the latest CT scanners, smartphone platform, new ICRP recommendations and anatomically realistic patient phantoms. © 2011, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2011

Volume

38

Issue

6

Start / End Page

3877

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ding, A., Schulte, N., Caracappa, P., & xu, X. (2011). TH‐E‐211‐06: Further Development of VirtualDose Software for CT Dose Assessment: Realistic Phantoms and Smartphone User Interfaces. In Medical Physics (Vol. 38, p. 3877). https://doi.org/10.1118/1.3613601
Ding, A., N. Schulte, P. Caracappa, and X. xu. “TH‐E‐211‐06: Further Development of VirtualDose Software for CT Dose Assessment: Realistic Phantoms and Smartphone User Interfaces.” In Medical Physics, 38:3877, 2011. https://doi.org/10.1118/1.3613601.
Ding, A., et al. “TH‐E‐211‐06: Further Development of VirtualDose Software for CT Dose Assessment: Realistic Phantoms and Smartphone User Interfaces.” Medical Physics, vol. 38, no. 6, 2011, p. 3877. Scopus, doi:10.1118/1.3613601.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2011

Volume

38

Issue

6

Start / End Page

3877

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences