Skip to main content
Journal cover image

Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements.

Publication ,  Journal Article
González-García, AO; Vizzeri, G; Bowd, C; Medeiros, FA; Zangwill, LM; Weinreb, RN
Published in: Am J Ophthalmol
June 2009

PURPOSE: To evaluate RTVue spectral-domain optical coherence tomography (OCT) (Optovue Inc, Fremont, California, USA) reproducibility and to assess agreement with Stratus time-domain OCT (Carl Zeiss Meditec, Dublin, California, USA) measurements. DESIGN: Observational clinical study. METHODS: Scans were obtained from both eyes of all participants 3 times using the RTVue nerve head map 4-mm diameter protocol and once using Stratus OCT within the same session. RTVue reproducibility and agreement with Stratus OCT were evaluated for retinal nerve fiber layer (RNFL) and optic disc measurements. RESULTS: Thirty healthy participants (60 eyes) and 38 glaucoma patients (76 eyes) were included in the study. RTVue reproducibility was good in both healthy participants and patients. For average RNFL thickness, the intraclass correlation coefficients in healthy eyes and patient eyes were 0.97 whereas for rim area they were 0.97 and 0.96, respectively. The correlation between RTVue and Stratus measurements generally was good, especially for average RNFL thickness (healthy eyes and patient eyes, r(2) = 0.82 and 0.86, respectively) and rim volume (healthy eyes and patient eyes, r(2) = 0.78 and 0.76, respectively). Bland-Altman plots showed good agreement between the instruments, with better agreement for average RNFL thickness (95% limits of agreement in healthy eyes and patient eyes, -8.6 to 12 microm and -5.6 to -14.8 microm, respectively) than optic disc parameters. Cup-to-disc ratio 95% limits of agreement in healthy eyes and patient eyes were -0.3 to 0.4 and -0.2 to 0.3, respectively. Optic disc measurements with RTVue were smaller than those with Stratus OCT (eg, disc area was on average 0.4 mm(2) smaller and rim area was 0.3 mm(2) smaller with RTVue). CONCLUSIONS: Reproducibility of RTVue RNFL and optic disc measurements was excellent in both groups. The level of agreement between RTVue and Stratus measurements suggests that RTVue has the potential to detect glaucomatous structural changes.

Duke Scholars

Published In

Am J Ophthalmol

DOI

EISSN

1879-1891

Publication Date

June 2009

Volume

147

Issue

6

Start / End Page

1067 / 1074.e1

Location

United States

Related Subject Headings

  • Visual Fields
  • Tonometry, Ocular
  • Tomography, Optical Coherence
  • Retinal Ganglion Cells
  • Reproducibility of Results
  • Prospective Studies
  • Optic Nerve Diseases
  • Optic Disk
  • Ophthalmology & Optometry
  • Nerve Fibers
 

Citation

APA
Chicago
ICMJE
MLA
NLM
González-García, A. O., Vizzeri, G., Bowd, C., Medeiros, F. A., Zangwill, L. M., & Weinreb, R. N. (2009). Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements. Am J Ophthalmol, 147(6), 1067-1074.e1. https://doi.org/10.1016/j.ajo.2008.12.032
González-García, Alberto O., Gianmarco Vizzeri, Christopher Bowd, Felipe A. Medeiros, Linda M. Zangwill, and Robert N. Weinreb. “Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements.Am J Ophthalmol 147, no. 6 (June 2009): 1067-1074.e1. https://doi.org/10.1016/j.ajo.2008.12.032.
González-García AO, Vizzeri G, Bowd C, Medeiros FA, Zangwill LM, Weinreb RN. Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements. Am J Ophthalmol. 2009 Jun;147(6):1067-1074.e1.
González-García, Alberto O., et al. “Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements.Am J Ophthalmol, vol. 147, no. 6, June 2009, pp. 1067-1074.e1. Pubmed, doi:10.1016/j.ajo.2008.12.032.
González-García AO, Vizzeri G, Bowd C, Medeiros FA, Zangwill LM, Weinreb RN. Reproducibility of RTVue retinal nerve fiber layer thickness and optic disc measurements and agreement with Stratus optical coherence tomography measurements. Am J Ophthalmol. 2009 Jun;147(6):1067-1074.e1.
Journal cover image

Published In

Am J Ophthalmol

DOI

EISSN

1879-1891

Publication Date

June 2009

Volume

147

Issue

6

Start / End Page

1067 / 1074.e1

Location

United States

Related Subject Headings

  • Visual Fields
  • Tonometry, Ocular
  • Tomography, Optical Coherence
  • Retinal Ganglion Cells
  • Reproducibility of Results
  • Prospective Studies
  • Optic Nerve Diseases
  • Optic Disk
  • Ophthalmology & Optometry
  • Nerve Fibers