Skip to main content

Optimal tether configurations and preload tensioning to prevent proximal junctional kyphosis: A finite element analysis

Publication ,  Journal Article
Buell, TJ; Bess, S; Xu, M; Schwab, FJ; Lafage, V; Ames, CP; Shaffrey, CI; Smith, JS
Published in: Journal of Neurosurgery: Spine
May 1, 2019

OBJECTIVE Proximal junctional kyphosis (PJK) is, in part, due to altered segmental biomechanics at the junction of rigid instrumented spine and relatively hypermobile non-instrumented adjacent segments. Proper application of posteriorly anchored polyethylene tethers (i.e., optimal configuration and tension) may mitigate adjacent-segment stress and help prevent PJK. The purpose of this study was to investigate the impact of different tether configurations and tensioning (preloading) on junctional range-of-motion (ROM) and other biomechanical indices for PJK in long instrumented spine constructs. METHODS Using a validated finite element model of a T7–L5 spine segment, testing was performed on intact spine, a multilevel posterior screw-rod construct (PS construct; T11–L5) without tether, and 15 PS constructs with different tether configurations that varied according to 1) proximal tether fixation of upper instrumented vertebra +1 (UIV+1) and/ or UIV+2; 2) distal tether fixation to UIV, to UIV−1, or to rods; and 3) use of a loop (single proximal fixation) or weave (UIV and/or UIV+1 fixation in addition to UIV+1 and/or UIV+2 proximal attachment) of the tether. Segmental ROM, intradiscal pressure (IDP), inter- and supraspinous ligament (ISL/SSL) forces, and screw loads were assessed under variable tether preload. RESULTS PS construct junctional ROM increased abruptly from 10% (T11–12) to 99% (T10–11) of baseline. After tethers were grouped by most cranial proximal fixation (UIV+1 vs UIV+2) and use of loop versus weave, UIV+2 Loop and/or Weave most effectively dampened junctional ROM and adjacent-segment stress. Different distal fixation and use of loop versus weave had minimal effect. The mean segmental ROM at T11–12, T10–11, and T9–10, respectively, was 6%, 40%, and 99% for UIV+1 Loop; 6%, 44%, and 99% for UIV+1 Weave; 5%, 23%, and 26% for UIV+2 Loop; and 5%, 24%, and 31% for UIV+2 Weave. Tethers shared loads with posterior ligaments; consequently, increasing tether preload tension reduced ISL/SSL forces, but screw loads increased. Further attenuation of junctional ROM and IDP reversed above approximately 100 N tether preload, suggesting diminished benefit for biomechanical PJK prophylaxis at higher preload tensioning. CONCLUSIONS In this study, finite element analysis demonstrated UIV+2 Loop and/or Weave tether configurations most effectively mitigated adjacent-segment stress in long instrumented spine constructs. Tether preload dampened ligament forces at the expense of screw loads, and an inflection point (approximately 100 N) was demonstrated above which junctional ROM and IDP worsened (i.e., avoid over-tightening tethers). Results suggest tether configuration and tension influence PJK biomechanics and further clinical research is warranted.

Duke Scholars

Published In

Journal of Neurosurgery: Spine

DOI

EISSN

1547-5646

ISSN

1547-5654

Publication Date

May 1, 2019

Volume

30

Issue

5

Start / End Page

574 / 584

Related Subject Headings

  • Orthopedics
  • 3209 Neurosciences
  • 1109 Neurosciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Buell, T. J., Bess, S., Xu, M., Schwab, F. J., Lafage, V., Ames, C. P., … Smith, J. S. (2019). Optimal tether configurations and preload tensioning to prevent proximal junctional kyphosis: A finite element analysis. Journal of Neurosurgery: Spine, 30(5), 574–584. https://doi.org/10.3171/2018.10.SPINE18429
Buell, T. J., S. Bess, M. Xu, F. J. Schwab, V. Lafage, C. P. Ames, C. I. Shaffrey, and J. S. Smith. “Optimal tether configurations and preload tensioning to prevent proximal junctional kyphosis: A finite element analysis.” Journal of Neurosurgery: Spine 30, no. 5 (May 1, 2019): 574–84. https://doi.org/10.3171/2018.10.SPINE18429.
Buell TJ, Bess S, Xu M, Schwab FJ, Lafage V, Ames CP, et al. Optimal tether configurations and preload tensioning to prevent proximal junctional kyphosis: A finite element analysis. Journal of Neurosurgery: Spine. 2019 May 1;30(5):574–84.
Buell, T. J., et al. “Optimal tether configurations and preload tensioning to prevent proximal junctional kyphosis: A finite element analysis.” Journal of Neurosurgery: Spine, vol. 30, no. 5, May 2019, pp. 574–84. Scopus, doi:10.3171/2018.10.SPINE18429.
Buell TJ, Bess S, Xu M, Schwab FJ, Lafage V, Ames CP, Shaffrey CI, Smith JS. Optimal tether configurations and preload tensioning to prevent proximal junctional kyphosis: A finite element analysis. Journal of Neurosurgery: Spine. 2019 May 1;30(5):574–584.

Published In

Journal of Neurosurgery: Spine

DOI

EISSN

1547-5646

ISSN

1547-5654

Publication Date

May 1, 2019

Volume

30

Issue

5

Start / End Page

574 / 584

Related Subject Headings

  • Orthopedics
  • 3209 Neurosciences
  • 1109 Neurosciences
  • 1103 Clinical Sciences