Skip to main content

Impact of energy threshold on material quantification of contrast agents in photon-counting CT

Publication ,  Conference
Rajagopal, JR; Sahbaee, P; Abadi, E; Negussie, AH; Pritchard, WF; Wood, BJ; Jones, EC; Samei, E
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
January 1, 2019

The purpose of this study was to examine the effect of energy threshold selection on the quantification of contrast agents in photon-counting CT (PCCT). A phantom was devised consisting of vials of iodine (4, 8, 16 mg/mL), gadolinium (4, 8, 16 mg/mL), and bismuth (5, 10, 15 mg/mL) within a cylindrical water container. The phantom was scanned on a prototype photon-counting CT scanner. The detected photons were binned into two energy bins using a fixed lower threshold of 20 keV and an upper threshold that varied between 50 to 90 keV. An image containing all the spectral information (threshold 1) was examined along with both binned images. Images were evaluated for the mean and standard deviation of CT number in each vial and contrast-to-noise ratio (CNR) for each concentration. CT number values in the threshold 1 image remained mostly unchanged as energy threshold was increased. Vials of iodine and gadolinium had slightly higher CT numbers in lower energy bin images than the threshold 1 images, but the percentage difference varied slightly (6-37% for iodine and 5-22% for gadolinium) with energy threshold. In higher energy bin images, CT numbers were lower (20-68% for iodine and 10-59% for gadolinium) than threshold 1 and the difference decreased with increasing energy threshold. For bismuth, the percentage difference in the lower bin decreased (by 11-19%) with energy level while it increased (by 18-23%) in the upper bin. CNR varied only slightly in the lower energy bins and decreased with increasing energy threshold for all materials.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

ISBN

9781510625433

Publication Date

January 1, 2019

Volume

10948
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Rajagopal, J. R., Sahbaee, P., Abadi, E., Negussie, A. H., Pritchard, W. F., Wood, B. J., … Samei, E. (2019). Impact of energy threshold on material quantification of contrast agents in photon-counting CT. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE (Vol. 10948). https://doi.org/10.1117/12.2512944
Rajagopal, J. R., P. Sahbaee, E. Abadi, A. H. Negussie, W. F. Pritchard, B. J. Wood, E. C. Jones, and E. Samei. “Impact of energy threshold on material quantification of contrast agents in photon-counting CT.” In Progress in Biomedical Optics and Imaging - Proceedings of SPIE, Vol. 10948, 2019. https://doi.org/10.1117/12.2512944.
Rajagopal JR, Sahbaee P, Abadi E, Negussie AH, Pritchard WF, Wood BJ, et al. Impact of energy threshold on material quantification of contrast agents in photon-counting CT. In: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2019.
Rajagopal, J. R., et al. “Impact of energy threshold on material quantification of contrast agents in photon-counting CT.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 10948, 2019. Scopus, doi:10.1117/12.2512944.
Rajagopal JR, Sahbaee P, Abadi E, Negussie AH, Pritchard WF, Wood BJ, Jones EC, Samei E. Impact of energy threshold on material quantification of contrast agents in photon-counting CT. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2019.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

ISBN

9781510625433

Publication Date

January 1, 2019

Volume

10948