Skip to main content
Journal cover image

Radiomic feature reproducibility in contrast-enhanced CT of the pancreas is affected by variabilities in scan parameters and manual segmentation.

Publication ,  Journal Article
Yamashita, R; Perrin, T; Chakraborty, J; Chou, JF; Horvat, N; Koszalka, MA; Midya, A; Gonen, M; Allen, P; Jarnagin, WR; Simpson, AL; Do, RKG
Published in: Eur Radiol
January 2020

OBJECTIVES: This study aims to measure the reproducibility of radiomic features in pancreatic parenchyma and ductal adenocarcinomas (PDAC) in patients who underwent consecutive contrast-enhanced computed tomography (CECT) scans. METHODS: In this IRB-approved and HIPAA-compliant retrospective study, 37 pairs of scans from 37 unique patients who underwent CECTs within a 2-week interval were included in the analysis of the reproducibility of features derived from pancreatic parenchyma, and a subset of 18 pairs of scans were further analyzed for the reproducibility of features derived from PDAC. In each patient, pancreatic parenchyma and pancreatic tumor (when present) were manually segmented by two radiologists independently. A total of 266 radiomic features were extracted from the pancreatic parenchyma and tumor region and also the volume and diameter of the tumor. The concordance correlation coefficient (CCC) was calculated to assess feature reproducibility for each patient in three scenarios: (1) different radiologists, same CECT; (2) same radiologist, different CECTs; and (3) different radiologists, different CECTs. RESULTS: Among pancreatic parenchyma-derived features, using a threshold of CCC > 0.90, 58/266 (21.8%) and 48/266 (18.1%) features met the threshold for scenario 1, 14/266 (5.3%) and 15/266 (5.6%) for scenario 2, and 14/266 (5.3%) and 10/266 (3.8%) for scenario 3. Among pancreatic tumor-derived features, 11/268 (4.1%) and 17/268 (6.3%) features met the threshold for scenario 1, 1/268 (0.4%) and 5/268 (1.9%) features met the threshold for scenario 2, and no features for scenario 3 met the threshold, respectively. CONCLUSIONS: Variations between CECT scans affected radiomic feature reproducibility to a greater extent than variation in segmentation. A smaller number of pancreatic tumor-derived radiomic features were reproducible compared with pancreatic parenchyma-derived radiomic features under the same conditions. KEY POINTS: • For pancreatic-derived radiomic features from contrast-enhanced CT (CECT), fewer than 25% are reproducible (with a threshold of CCC < 0.9) in a clinical heterogeneous dataset. • Variations between CECT scans affected the number of reproducible radiomic features to a greater extent than variations in radiologist segmentation. • A smaller number of pancreatic tumor-derived radiomic features were reproducible compared with pancreatic parenchyma-derived radiomic features under the same conditions.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Eur Radiol

DOI

EISSN

1432-1084

Publication Date

January 2020

Volume

30

Issue

1

Start / End Page

195 / 205

Location

Germany

Related Subject Headings

  • Tomography, X-Ray Computed
  • Retrospective Studies
  • Reproducibility of Results
  • Parenchymal Tissue
  • Pancreatic Neoplasms
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Yamashita, R., Perrin, T., Chakraborty, J., Chou, J. F., Horvat, N., Koszalka, M. A., … Do, R. K. G. (2020). Radiomic feature reproducibility in contrast-enhanced CT of the pancreas is affected by variabilities in scan parameters and manual segmentation. Eur Radiol, 30(1), 195–205. https://doi.org/10.1007/s00330-019-06381-8
Yamashita, Rikiya, Thomas Perrin, Jayasree Chakraborty, Joanne F. Chou, Natally Horvat, Maura A. Koszalka, Abhishek Midya, et al. “Radiomic feature reproducibility in contrast-enhanced CT of the pancreas is affected by variabilities in scan parameters and manual segmentation.Eur Radiol 30, no. 1 (January 2020): 195–205. https://doi.org/10.1007/s00330-019-06381-8.
Yamashita R, Perrin T, Chakraborty J, Chou JF, Horvat N, Koszalka MA, et al. Radiomic feature reproducibility in contrast-enhanced CT of the pancreas is affected by variabilities in scan parameters and manual segmentation. Eur Radiol. 2020 Jan;30(1):195–205.
Yamashita, Rikiya, et al. “Radiomic feature reproducibility in contrast-enhanced CT of the pancreas is affected by variabilities in scan parameters and manual segmentation.Eur Radiol, vol. 30, no. 1, Jan. 2020, pp. 195–205. Pubmed, doi:10.1007/s00330-019-06381-8.
Yamashita R, Perrin T, Chakraborty J, Chou JF, Horvat N, Koszalka MA, Midya A, Gonen M, Allen P, Jarnagin WR, Simpson AL, Do RKG. Radiomic feature reproducibility in contrast-enhanced CT of the pancreas is affected by variabilities in scan parameters and manual segmentation. Eur Radiol. 2020 Jan;30(1):195–205.
Journal cover image

Published In

Eur Radiol

DOI

EISSN

1432-1084

Publication Date

January 2020

Volume

30

Issue

1

Start / End Page

195 / 205

Location

Germany

Related Subject Headings

  • Tomography, X-Ray Computed
  • Retrospective Studies
  • Reproducibility of Results
  • Parenchymal Tissue
  • Pancreatic Neoplasms
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Humans
  • Female