High sensitivity dedicated dual-breast PET/MR imaging: concept and preliminary simulations

Publication ,  Journal Article
Tornai, M; Samanta, S; Majewski, S; Williams, M; Turkington, T; Register, A; Jiang, J; Dolinsky, S; O'Sullivan, J; Tai, Y-C
Published in: Proceedings of SPIE
May 22, 2020

This paper presents a new high-sensitivity PET geometry for high fidelity MRI-compatible PET breast imaging which can scan both breasts simultaneously and have: high sensitivity and resolution; compatibility with MR-breast imaged volume; complete visualization of both breasts, mediastinum and axilla; and a modular design. Whereas contemporary dedicated x-ray and molecular breast imaging devices only scan one breast at a time, this approach relies on an unconventional PET geometry, and is able to provide a PET field of view (FOV) larger than that from dedicated breast MRI. The system geometry is evaluated with GATE Monte Carlo simulations of intrinsic system parameters. Various sized lesions (4-6mm) having [6:1 to 4:1] lesion:background radioactivity ratios mimicking different biological uptake are simulated, strategically located throughout a volumetric anthropomorphic torso. Dedicated breast PET (dbPET) imaging is compared with contemporary clinical PET. The dbPET system sensitivity is >6X greater than for contemporary whole-body PET. The novel, non-conventional system geometry allows for simultaneous dual-breast imaging, along with full medial and axillary imaging. Iteratively reconstructed full-volumetric images illustrate sharper visualization of 4mm lower uptake [4:1] lesions throughout the FOV compared with clinical PET. Image overlap between dedicated breast PET and MRI FOVs is excellent. Simulation results indicate clear superiority over conventional, high-sensitivity whole-body PET systems, as well as improved sensitivity over single-breast dbPET systems. This proposed system potentially facilitates both early detection and diagnosis, especially by increasing specificity of MRI, as well as visualizing tissue heterogeneity, monitoring therapeutic efficacy, and detecting breast cancer recurrence throughout the entire mediastinum.

Duke Scholars

Published In

Proceedings of SPIE

DOI

Publication Date

May 22, 2020

Volume

11513

Issue

1151318

Start / End Page

1151318-1 / 1151318-6

Location

USA

Publisher

SPIE
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tornai, M., Samanta, S., Majewski, S., Williams, M., Turkington, T., Register, A., … Tai, Y.-C. (2020). High sensitivity dedicated dual-breast PET/MR imaging: concept and preliminary simulations. Proceedings of SPIE, 11513(1151318), 1151318-1-1151318–6. https://doi.org/10.1117/12.2563650
Tornai, Martin, Suranjana Samanta, Stanislaw Majewski, Mark Williams, Timothy Turkington, Alan Register, Jianyong Jiang, Sergei Dolinsky, Joseph O’Sullivan, and Yuan-Chuan Tai. “High sensitivity dedicated dual-breast PET/MR imaging: concept and preliminary simulations.” Edited by Hilde Bosmans, Nicholas Marshall, and Chantal Van Ongeval. Proceedings of SPIE 11513, no. 1151318 (May 22, 2020): 1151318-1-1151318–6. https://doi.org/10.1117/12.2563650.
Tornai M, Samanta S, Majewski S, Williams M, Turkington T, Register A, et al. High sensitivity dedicated dual-breast PET/MR imaging: concept and preliminary simulations. Bosmans H, Marshall N, Van Ongeval C, editors. Proceedings of SPIE. 2020 May 22;11513(1151318):1151318-1-1151318–6.
Tornai, Martin, et al. “High sensitivity dedicated dual-breast PET/MR imaging: concept and preliminary simulations.” Proceedings of SPIE, edited by Hilde Bosmans et al., vol. 11513, no. 1151318, SPIE, May 2020, pp. 1151318-1-1151318–6. Manual, doi:10.1117/12.2563650.
Tornai M, Samanta S, Majewski S, Williams M, Turkington T, Register A, Jiang J, Dolinsky S, O’Sullivan J, Tai Y-C. High sensitivity dedicated dual-breast PET/MR imaging: concept and preliminary simulations. Bosmans H, Marshall N, Van Ongeval C, editors. Proceedings of SPIE. SPIE; 2020 May 22;11513(1151318):1151318-1-1151318–6.

Published In

Proceedings of SPIE

DOI

Publication Date

May 22, 2020

Volume

11513

Issue

1151318

Start / End Page

1151318-1 / 1151318-6

Location

USA

Publisher

SPIE