Skip to main content
Journal cover image

Diastolic Function and Clinical Outcomes After Transcatheter Aortic Valve Replacement: PARTNER 2 SAPIEN 3 Registry.

Publication ,  Journal Article
Ong, G; Pibarot, P; Redfors, B; Weissman, NJ; Jaber, WA; Makkar, RR; Lerakis, S; Gopal, D; Khalique, O; Kodali, SK; Thourani, VH; McAndrew, T ...
Published in: J Am Coll Cardiol
December 22, 2020

BACKGROUND: Few studies have evaluated if diastolic function could predict outcomes in patients with aortic stenosis. OBJECTIVES: The authors aimed to assess the association between diastolic dysfunction (DD) and outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR). METHODS: Baseline, 30-day, and 1- and 2-year transthoracic echocardiograms from the PARTNER (Placement of Aortic Transcatheter Valves) 2 SAPIEN 3 registry were analyzed by a consortium of core laboratories and divided into the American Society of Echocardiography DD groups. RESULTS: Among the 1,750 included, 682 (54.4%) had grade 1 DD, 352 (28.1%) had grade 2 DD, 168 (13.4%) had grade 3 DD, and 51 (4.1%) had indeterminate DD grade. Incremental baseline grades of DD were associated with an increase in combined 1- and 2-year cardiovascular (CV) death/rehospitalization (all p < 0.002) and all-cause death at 2 years (p = 0.01) but not at 1 year. Improvement in DD grade/grade 1 DD at 30 days post-TAVR was seen in 70.8% patients. Patients with improvement in ≥1 grade of DD/grade 1 DD had reduced 1-year CV death/rehospitalization (p < 0.001) and increased 2-year survival (p = 0.01). Baseline grade 3 DD was a predictor of 1-year CV death/rehospitalization (hazard ratio: 2.73; 95% confidence interval: 1.07 to 6.98; p = 0.04). Improvement in DD grade/grade 1 DD at 30 days was protective for 1-year CV death/rehospitalizations (hazard ratio: 0.39; 95% confidence interval: 0.19 to 0.83; p = 0.01). CONCLUSIONS: In the PARTNER 2 SAPIEN 3 registry, baseline DD was a predictor of up to 2 years clinical outcomes in patients who underwent TAVR. Improvement in DD grade at 30 days was associated with improvement in short-term clinical outcomes. (The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - PARTNER II - PARTNERII - S3 Intermediate [PARTNERII S3i]; NCT03222128; PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - High Risk and Nested Registry 7 [PII S3HR/NR7]; NCT03222141).

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

J Am Coll Cardiol

DOI

EISSN

1558-3597

Publication Date

December 22, 2020

Volume

76

Issue

25

Start / End Page

2940 / 2951

Location

United States

Related Subject Headings

  • United States
  • Transcatheter Aortic Valve Replacement
  • Survival Analysis
  • Prognosis
  • Postoperative Complications
  • Patient Readmission
  • Outcome and Process Assessment, Health Care
  • Male
  • Humans
  • Heart Failure, Diastolic
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ong, G., Pibarot, P., Redfors, B., Weissman, N. J., Jaber, W. A., Makkar, R. R., … Hahn, R. T. (2020). Diastolic Function and Clinical Outcomes After Transcatheter Aortic Valve Replacement: PARTNER 2 SAPIEN 3 Registry. J Am Coll Cardiol, 76(25), 2940–2951. https://doi.org/10.1016/j.jacc.2020.10.032
Ong, Geraldine, Philippe Pibarot, Bjorn Redfors, Neil J. Weissman, Wael A. Jaber, Raj R. Makkar, Stamatios Lerakis, et al. “Diastolic Function and Clinical Outcomes After Transcatheter Aortic Valve Replacement: PARTNER 2 SAPIEN 3 Registry.J Am Coll Cardiol 76, no. 25 (December 22, 2020): 2940–51. https://doi.org/10.1016/j.jacc.2020.10.032.
Ong G, Pibarot P, Redfors B, Weissman NJ, Jaber WA, Makkar RR, et al. Diastolic Function and Clinical Outcomes After Transcatheter Aortic Valve Replacement: PARTNER 2 SAPIEN 3 Registry. J Am Coll Cardiol. 2020 Dec 22;76(25):2940–51.
Ong, Geraldine, et al. “Diastolic Function and Clinical Outcomes After Transcatheter Aortic Valve Replacement: PARTNER 2 SAPIEN 3 Registry.J Am Coll Cardiol, vol. 76, no. 25, Dec. 2020, pp. 2940–51. Pubmed, doi:10.1016/j.jacc.2020.10.032.
Ong G, Pibarot P, Redfors B, Weissman NJ, Jaber WA, Makkar RR, Lerakis S, Gopal D, Khalique O, Kodali SK, Thourani VH, Anwaruddin S, McAndrew T, Zhang Y, Alu MC, Douglas PS, Hahn RT. Diastolic Function and Clinical Outcomes After Transcatheter Aortic Valve Replacement: PARTNER 2 SAPIEN 3 Registry. J Am Coll Cardiol. 2020 Dec 22;76(25):2940–2951.
Journal cover image

Published In

J Am Coll Cardiol

DOI

EISSN

1558-3597

Publication Date

December 22, 2020

Volume

76

Issue

25

Start / End Page

2940 / 2951

Location

United States

Related Subject Headings

  • United States
  • Transcatheter Aortic Valve Replacement
  • Survival Analysis
  • Prognosis
  • Postoperative Complications
  • Patient Readmission
  • Outcome and Process Assessment, Health Care
  • Male
  • Humans
  • Heart Failure, Diastolic