Skip to main content

Swept-Source Anatomic Optical Coherence Elastography of Porcine Trachea.

Publication ,  Conference
Bu, R; Price, H; Mitran, S; Zdanski, C; Oldenburg, AL
Published in: Proceedings of SPIE--the International Society for Optical Engineering
January 2016

Quantitative endoscopic imaging is at the vanguard of novel techniques in the assessment upper airway obstruction. Anatomic optical coherence tomography (aOCT) has the potential to provide the geometry of the airway lumen with high-resolution and in 4 dimensions. By coupling aOCT with measurements of pressure, optical coherence elastography (OCE) can be performed to characterize airway wall stiffness. This can aid in identifying regions of dynamic collapse as well as informing computational fluid dynamics modeling to aid in surgical decision-making. Toward this end, here we report on an anatomic optical coherence tomography (aOCT) system powered by a wavelength-swept laser source. The system employs a fiber-optic catheter with outer diameter of 0.82 mm deployed via the bore of a commercial, flexible bronchoscope. Helical scans are performed to measure the airway geometry and to quantify the cross-sectional-area (CSA) of the airway. We report on a preliminary validation of aOCT for elastography, in which aOCT-derived CSA was obtained as a function of pressure to estimate airway wall compliance. Experiments performed on a Latex rubber tube resulted in a compliance measurement of 0.68±0.02 mm2/cmH2O, with R2=0.98 over the pressure range from 10 to 40 cmH2O. Next, ex vivo porcine trachea was studied, resulting in a measured compliance from 1.06±0.12 to 3.34±0.44 mm2/cmH2O, (R2>0.81). The linearity of the data confirms the elastic nature of the airway. The compliance values are within the same order-of-magnitude as previous measurements of human upper airways, suggesting that this system is capable of assessing airway wall compliance in future human studies.

Duke Scholars

Published In

Proceedings of SPIE--the International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

January 2016

Volume

9689

Start / End Page

968923

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Bu, R., Price, H., Mitran, S., Zdanski, C., & Oldenburg, A. L. (2016). Swept-Source Anatomic Optical Coherence Elastography of Porcine Trachea. In Proceedings of SPIE--the International Society for Optical Engineering (Vol. 9689, p. 968923). https://doi.org/10.1117/12.2213186
Bu, Ruofei, Hillel Price, Sorin Mitran, Carlton Zdanski, and Amy L. Oldenburg. “Swept-Source Anatomic Optical Coherence Elastography of Porcine Trachea.” In Proceedings of SPIE--the International Society for Optical Engineering, 9689:968923, 2016. https://doi.org/10.1117/12.2213186.
Bu R, Price H, Mitran S, Zdanski C, Oldenburg AL. Swept-Source Anatomic Optical Coherence Elastography of Porcine Trachea. In: Proceedings of SPIE--the International Society for Optical Engineering. 2016. p. 968923.
Bu, Ruofei, et al. “Swept-Source Anatomic Optical Coherence Elastography of Porcine Trachea.Proceedings of SPIE--the International Society for Optical Engineering, vol. 9689, 2016, p. 968923. Epmc, doi:10.1117/12.2213186.
Bu R, Price H, Mitran S, Zdanski C, Oldenburg AL. Swept-Source Anatomic Optical Coherence Elastography of Porcine Trachea. Proceedings of SPIE--the International Society for Optical Engineering. 2016. p. 968923.

Published In

Proceedings of SPIE--the International Society for Optical Engineering

DOI

EISSN

1996-756X

ISSN

0277-786X

Publication Date

January 2016

Volume

9689

Start / End Page

968923

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering