Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure.

Publication ,  Journal Article
Wick, CA; McClellan, JH; Arepalli, CD; Auffermann, WF; Henry, TS; Khosa, F; Coy, AM; Tridandapani, S
Published in: Med Phys
February 2015

PURPOSE: Accurate knowledge of cardiac quiescence is crucial to the performance of many cardiac imaging modalities, including computed tomography coronary angiography (CTCA). To accurately quantify quiescence, a method for detecting the quiescent periods of the heart from retrospective cardiac computed tomography (CT) using a correlation-based, phase-to-phase deviation measure was developed. METHODS: Retrospective cardiac CT data were obtained from 20 patients (11 male, 9 female, 33-74 yr) and the left main, left anterior descending, left circumflex, right coronary artery (RCA), and interventricular septum (IVS) were segmented for each phase using a semiautomated technique. Cardiac motion of individual coronary vessels as well as the IVS was calculated using phase-to-phase deviation. As an easily identifiable feature, the IVS was analyzed to assess how well it predicts vessel quiescence. Finally, the diagnostic quality of the reconstructed volumes from the quiescent phases determined using the deviation measure from the vessels in aggregate and the IVS was compared to that from quiescent phases calculated by the CT scanner. Three board-certified radiologists, fellowship-trained in cardiothoracic imaging, graded the diagnostic quality of the reconstructions using a Likert response format: 1 = excellent, 2 = good, 3 = adequate, 4 = nondiagnostic. RESULTS: Systolic and diastolic quiescent periods were identified for each subject from the vessel motion calculated using the phase-to-phase deviation measure. The motion of the IVS was found to be similar to the aggregate vessel (AGG) motion. The diagnostic quality of the coronary vessels for the quiescent phases calculated from the aggregate vessel (PAGG) and IVS (PIV S) deviation signal using the proposed methods was comparable to the quiescent phases calculated by the CT scanner (PCT). The one exception was the RCA, which improved for PAGG for 18 of the 20 subjects when compared to PCT (PCT = 2.48; PAGG = 2.07, p = 0.001). CONCLUSIONS: A method for quantifying the motion of specific coronary vessels using a correlation-based, phase-to-phase deviation measure was developed and tested on 20 patients receiving cardiac CT exams. The IVS was found to be a suitable predictor of vessel quiescence. The diagnostic quality of the quiescent phases detected by the proposed methods was comparable to those calculated by the CT scanner. The ability to quantify coronary vessel quiescence from the motion of the IVS can be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

February 2015

Volume

42

Issue

2

Start / End Page

983 / 993

Location

United States

Related Subject Headings

  • Ventricular Septum
  • Tomography, X-Ray Computed
  • Retrospective Studies
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Image Processing, Computer-Assisted
  • Humans
  • Heart
  • Female
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wick, C. A., McClellan, J. H., Arepalli, C. D., Auffermann, W. F., Henry, T. S., Khosa, F., … Tridandapani, S. (2015). Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure. Med Phys, 42(2), 983–993. https://doi.org/10.1118/1.4906246
Wick, Carson A., James H. McClellan, Chesnal D. Arepalli, William F. Auffermann, Travis S. Henry, Faisal Khosa, Adam M. Coy, and Srini Tridandapani. “Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure.Med Phys 42, no. 2 (February 2015): 983–93. https://doi.org/10.1118/1.4906246.
Wick CA, McClellan JH, Arepalli CD, Auffermann WF, Henry TS, Khosa F, et al. Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure. Med Phys. 2015 Feb;42(2):983–93.
Wick, Carson A., et al. “Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure.Med Phys, vol. 42, no. 2, Feb. 2015, pp. 983–93. Pubmed, doi:10.1118/1.4906246.
Wick CA, McClellan JH, Arepalli CD, Auffermann WF, Henry TS, Khosa F, Coy AM, Tridandapani S. Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure. Med Phys. 2015 Feb;42(2):983–993.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

February 2015

Volume

42

Issue

2

Start / End Page

983 / 993

Location

United States

Related Subject Headings

  • Ventricular Septum
  • Tomography, X-Ray Computed
  • Retrospective Studies
  • Nuclear Medicine & Medical Imaging
  • Middle Aged
  • Male
  • Image Processing, Computer-Assisted
  • Humans
  • Heart
  • Female