Skip to main content
Journal cover image

Clinical evaluation of the BioFire Global Fever Panel for the identification of malaria, leptospirosis, chikungunya, and dengue from whole blood: a prospective, multicentre, cross-sectional diagnostic accuracy study.

Publication ,  Journal Article
Manabe, YC; Betz, J; Jackson, O; Asoala, V; Bazan, I; Blair, PW; Chang, A; Chusri, S; Crump, JA; Edgel, KA; Faix, DJ; Fernandez, S; Fox, AT ...
Published in: Lancet Infect Dis
September 2022

BACKGROUND: Acute febrile illness is a common presentation for patients at hospitals globally. Assays that can diagnose a variety of common pathogens in blood could help to establish a diagnosis for targeted disease management. We aimed to evaluate the performance of the BioFire Global Fever Panel (GF Panel), a multiplex nucleic acid amplification test performed on whole blood specimens run on the BioFire FilmArray System, in the diagnosis of several pathogens that cause acute febrile illness. METHODS: We did a prospective, multicentre, cross-sectional diagnostic accuracy study to evaluate the GF Panel. Consenting adults and children older than 6 months presenting with fever in the previous 2 days were enrolled consecutively in sub-Saharan Africa (Ghana, Kenya, Tanzania, Uganda), southeast Asia (Cambodia, Thailand), central and South America (Honduras, Peru), and the USA (Washington, DC; St Louis, MO). We assessed the performance of six analytes (chikungunya virus, dengue virus [serotypes 1-4], Leptospira spp, Plasmodium spp, Plasmodium falciparum, and Plasmodium vivax or Plasmodium ovale) on the GF Panel. The performance of the GF Panel was assessed using comparator PCR assays with different primers followed by bidirectional sequencing on nucleic acid extracts from the same specimen. We calculated the positive percent agreement and negative percent agreement of the GF Panel with respect to the comparator assays. This study is registered with ClinicalTrials.gov, NCT02968355. FINDINGS: From March 26, 2018, to Sept 30, 2019, 1965 participants were enrolled at ten sites worldwide. Of the 1875 participants with analysable results, 980 (52·3%) were female and the median age was 22 years (range 0-100). At least one analyte was detected in 657 (35·0%) of 1875 specimens. The GF Panel had a positive percent agreement for the six analytes evaluated as follows: chikungunya virus 100% (95% CI 86·3-100), dengue virus 94·0% (90·6-96·5), Leptospira spp 93·8% (69·8-99·8), Plasmodium spp 98·3% (96·3-99·4), P falciparum 92·7% (88·8-95·6), and P vivax or P ovale 92·7% (86·7-96·6). The GF Panel had a negative percent agreement equal to or greater than 99·2% (98·6-99·6) for all analytes. INTERPRETATION: This 1 h sample-to-answer, molecular device can detect common causative agents of acute febrile illness with excellent positive percent agreement and negative percent agreement directly in whole blood. The targets of the assay are prevalent in tropical and subtropical regions globally, and the assay could help to provide both public health surveillance and individual diagnoses. FUNDING: BioFire Defense, Joint Project Manager for Medical Countermeasure Systems and US Army Medical Materiel Development Activity, and National Institute of Allergy and Infectious Diseases.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Lancet Infect Dis

DOI

EISSN

1474-4457

Publication Date

September 2022

Volume

22

Issue

9

Start / End Page

1356 / 1364

Location

United States

Related Subject Headings

  • Young Adult
  • Prospective Studies
  • Plasmodium
  • Middle Aged
  • Microbiology
  • Male
  • Malaria
  • Leptospirosis
  • Infant, Newborn
  • Infant
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Manabe, Y. C., Betz, J., Jackson, O., Asoala, V., Bazan, I., Blair, P. W., … Jones, B. W. (2022). Clinical evaluation of the BioFire Global Fever Panel for the identification of malaria, leptospirosis, chikungunya, and dengue from whole blood: a prospective, multicentre, cross-sectional diagnostic accuracy study. Lancet Infect Dis, 22(9), 1356–1364. https://doi.org/10.1016/S1473-3099(22)00290-0
Manabe, Yukari C., Joshua Betz, Olivia Jackson, Victor Asoala, Isabel Bazan, Paul W. Blair, Aileen Chang, et al. “Clinical evaluation of the BioFire Global Fever Panel for the identification of malaria, leptospirosis, chikungunya, and dengue from whole blood: a prospective, multicentre, cross-sectional diagnostic accuracy study.Lancet Infect Dis 22, no. 9 (September 2022): 1356–64. https://doi.org/10.1016/S1473-3099(22)00290-0.
Manabe YC, Betz J, Jackson O, Asoala V, Bazan I, Blair PW, Chang A, Chusri S, Crump JA, Edgel KA, Faix DJ, Fernandez S, Fox AT, Garcia JA, Grogl M, Hansen EA, Heang V, House SL, Jongsakul K, Kaburise MB, Klungthong C, Lamorde M, Letizia AG, Lorenzana I, Luy M, Maro VP, Mores CN, Myers CA, Oduro AR, Parham L, Porzucek AJ, Prouty M, Rabiger DS, Rubach MP, Siles C, Silva M, Ukachu C, Waitumbi JN, Phillips CL, Jones BW. Clinical evaluation of the BioFire Global Fever Panel for the identification of malaria, leptospirosis, chikungunya, and dengue from whole blood: a prospective, multicentre, cross-sectional diagnostic accuracy study. Lancet Infect Dis. 2022 Sep;22(9):1356–1364.
Journal cover image

Published In

Lancet Infect Dis

DOI

EISSN

1474-4457

Publication Date

September 2022

Volume

22

Issue

9

Start / End Page

1356 / 1364

Location

United States

Related Subject Headings

  • Young Adult
  • Prospective Studies
  • Plasmodium
  • Middle Aged
  • Microbiology
  • Male
  • Malaria
  • Leptospirosis
  • Infant, Newborn
  • Infant