Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect.

Publication ,  Journal Article
Barraclough, B; Li, JG; Lebron, S; Fan, Q; Liu, C; Yan, G
Published in: Med Phys
May 2016

PURPOSE: To investigate the geometry dependence of the detector response function (DRF) of three commonly used scanning ionization chambers and its impact on a convolution-based method to address the volume averaging effect (VAE). METHODS: A convolution-based approach has been proposed recently to address the ionization chamber VAE. It simulates the VAE in the treatment planning system (TPS) by iteratively convolving the calculated beam profiles with the DRF while optimizing the beam model. Since the convolved and the measured profiles are subject to the same VAE, the calculated profiles match the implicit "real" ones when the optimization converges. Three DRFs (Gaussian, Lorentzian, and parabolic function) were used for three ionization chambers (CC04, CC13, and SNC125c) in this study. Geometry dependent/independent DRFs were obtained by minimizing the difference between the ionization chamber-measured profiles and the diode-measured profiles convolved with the DRFs. These DRFs were used to obtain eighteen beam models for a commercial TPS. Accuracy of the beam models were evaluated by assessing the 20%-80% penumbra width difference (PWD) between the computed and diode-measured beam profiles. RESULTS: The convolution-based approach was found to be effective for all three ionization chambers with significant improvement for all beam models. Up to 17% geometry dependence of the three DRFs was observed for the studied ionization chambers. With geometry dependent DRFs, the PWD was within 0.80 mm for the parabolic function and CC04 combination and within 0.50 mm for other combinations; with geometry independent DRFs, the PWD was within 1.00 mm for all cases. When using the Gaussian function as the DRF, accounting for geometry dependence led to marginal improvement (PWD < 0.20 mm) for CC04; the improvement ranged from 0.38 to 0.65 mm for CC13; for SNC125c, the improvement was slightly above 0.50 mm. CONCLUSIONS: Although all three DRFs were found adequate to represent the response of the studied ionization chambers, the Gaussian function was favored due to its superior overall performance. The geometry dependence of the DRFs can be significant for clinical applications involving small fields such as stereotactic radiotherapy.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

May 2016

Volume

43

Issue

5

Start / End Page

2081

Location

United States

Related Subject Headings

  • Radiation Dosage
  • Particle Accelerators
  • Nuclear Medicine & Medical Imaging
  • Models, Theoretical
  • Algorithms
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Barraclough, B., Li, J. G., Lebron, S., Fan, Q., Liu, C., & Yan, G. (2016). Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect. Med Phys, 43(5), 2081. https://doi.org/10.1118/1.4944783
Barraclough, Brendan, Jonathan G. Li, Sharon Lebron, Qiyong Fan, Chihray Liu, and Guanghua Yan. “Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect.Med Phys 43, no. 5 (May 2016): 2081. https://doi.org/10.1118/1.4944783.
Barraclough, Brendan, et al. “Technical Note: Impact of the geometry dependence of the ion chamber detector response function on a convolution-based method to address the volume averaging effect.Med Phys, vol. 43, no. 5, May 2016, p. 2081. Pubmed, doi:10.1118/1.4944783.

Published In

Med Phys

DOI

EISSN

2473-4209

Publication Date

May 2016

Volume

43

Issue

5

Start / End Page

2081

Location

United States

Related Subject Headings

  • Radiation Dosage
  • Particle Accelerators
  • Nuclear Medicine & Medical Imaging
  • Models, Theoretical
  • Algorithms
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences