Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.
Publication
, Journal Article
Beckerman, Z; Cohen, O; Agmon, Y; Bolotin, G
Published in: Heart Surg Forum
April 2013
The strategy of transcatheter valve-in-valve implantation into failing mitral and aortic bioprosthetic valves is a documented approach. It allows one to avoid performing a high-risk repeat cardiac surgery in elderly patients with multiple comorbidities. Tricuspid valve-in-valve implantation has been documented only a few times in the literature. We report the case of a 65-year-old woman with a failing bioprosthetic tricuspid valve who had undergone 3 prior open heart operations. We attempted a transatrial transcatheter approach and successfully deployed a 29-mm Edwards Sapien balloon-expandable bioprosthesis into a severely stenotic tricuspid bioprosthesis. This case demonstrates the technical feasibility and safety of this approach.
Duke Scholars
Published In
Heart Surg Forum
DOI
EISSN
1522-6662
Publication Date
April 2013
Volume
16
Issue
2
Start / End Page
E96 / E98
Location
United States
Related Subject Headings
- Tricuspid Valve Stenosis
- Treatment Outcome
- Reoperation
- Prosthesis Failure
- Humans
- Heart Valve Prosthesis Implantation
- Heart Valve Prosthesis
- Female
- Cardiovascular System & Hematology
- Bioprosthesis
Citation
APA
Chicago
ICMJE
MLA
NLM
Beckerman, Z., Cohen, O., Agmon, Y., & Bolotin, G. (2013). Valve-in-valve in the tricuspid position for a stenosed bioprosthesis. Heart Surg Forum, 16(2), E96–E98. https://doi.org/10.1532/HSF98.20121106
Beckerman, Ziv, Oved Cohen, Yoram Agmon, and Gil Bolotin. “Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.” Heart Surg Forum 16, no. 2 (April 2013): E96–98. https://doi.org/10.1532/HSF98.20121106.
Beckerman Z, Cohen O, Agmon Y, Bolotin G. Valve-in-valve in the tricuspid position for a stenosed bioprosthesis. Heart Surg Forum. 2013 Apr;16(2):E96–8.
Beckerman, Ziv, et al. “Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.” Heart Surg Forum, vol. 16, no. 2, Apr. 2013, pp. E96–98. Pubmed, doi:10.1532/HSF98.20121106.
Beckerman Z, Cohen O, Agmon Y, Bolotin G. Valve-in-valve in the tricuspid position for a stenosed bioprosthesis. Heart Surg Forum. 2013 Apr;16(2):E96–E98.
Published In
Heart Surg Forum
DOI
EISSN
1522-6662
Publication Date
April 2013
Volume
16
Issue
2
Start / End Page
E96 / E98
Location
United States
Related Subject Headings
- Tricuspid Valve Stenosis
- Treatment Outcome
- Reoperation
- Prosthesis Failure
- Humans
- Heart Valve Prosthesis Implantation
- Heart Valve Prosthesis
- Female
- Cardiovascular System & Hematology
- Bioprosthesis