Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.

Publication ,  Journal Article
Beckerman, Z; Cohen, O; Agmon, Y; Bolotin, G
Published in: Heart Surg Forum
April 2013

The strategy of transcatheter valve-in-valve implantation into failing mitral and aortic bioprosthetic valves is a documented approach. It allows one to avoid performing a high-risk repeat cardiac surgery in elderly patients with multiple comorbidities. Tricuspid valve-in-valve implantation has been documented only a few times in the literature. We report the case of a 65-year-old woman with a failing bioprosthetic tricuspid valve who had undergone 3 prior open heart operations. We attempted a transatrial transcatheter approach and successfully deployed a 29-mm Edwards Sapien balloon-expandable bioprosthesis into a severely stenotic tricuspid bioprosthesis. This case demonstrates the technical feasibility and safety of this approach.

Duke Scholars

Published In

Heart Surg Forum

DOI

EISSN

1522-6662

Publication Date

April 2013

Volume

16

Issue

2

Start / End Page

E96 / E98

Location

United States

Related Subject Headings

  • Tricuspid Valve Stenosis
  • Treatment Outcome
  • Reoperation
  • Prosthesis Failure
  • Humans
  • Heart Valve Prosthesis Implantation
  • Heart Valve Prosthesis
  • Female
  • Cardiovascular System & Hematology
  • Bioprosthesis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Beckerman, Z., Cohen, O., Agmon, Y., & Bolotin, G. (2013). Valve-in-valve in the tricuspid position for a stenosed bioprosthesis. Heart Surg Forum, 16(2), E96–E98. https://doi.org/10.1532/HSF98.20121106
Beckerman, Ziv, Oved Cohen, Yoram Agmon, and Gil Bolotin. “Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.Heart Surg Forum 16, no. 2 (April 2013): E96–98. https://doi.org/10.1532/HSF98.20121106.
Beckerman Z, Cohen O, Agmon Y, Bolotin G. Valve-in-valve in the tricuspid position for a stenosed bioprosthesis. Heart Surg Forum. 2013 Apr;16(2):E96–8.
Beckerman, Ziv, et al. “Valve-in-valve in the tricuspid position for a stenosed bioprosthesis.Heart Surg Forum, vol. 16, no. 2, Apr. 2013, pp. E96–98. Pubmed, doi:10.1532/HSF98.20121106.
Beckerman Z, Cohen O, Agmon Y, Bolotin G. Valve-in-valve in the tricuspid position for a stenosed bioprosthesis. Heart Surg Forum. 2013 Apr;16(2):E96–E98.

Published In

Heart Surg Forum

DOI

EISSN

1522-6662

Publication Date

April 2013

Volume

16

Issue

2

Start / End Page

E96 / E98

Location

United States

Related Subject Headings

  • Tricuspid Valve Stenosis
  • Treatment Outcome
  • Reoperation
  • Prosthesis Failure
  • Humans
  • Heart Valve Prosthesis Implantation
  • Heart Valve Prosthesis
  • Female
  • Cardiovascular System & Hematology
  • Bioprosthesis