Absolute quantitation of endogenous proteins with precision and accuracy using a capillary Western system.

Publication ,  Journal Article
Chen, J-Q; Heldman, MR; Herrmann, MA; Kedei, N; Woo, W; Blumberg, PM; Goldsmith, PK
Published in: Anal Biochem
November 1, 2013

Precise and accurate quantification of protein expression levels in a complex biological setting is challenging. Here, we describe a method for absolute quantitation of endogenous proteins in cell lysates using an automated capillary immunoassay system, the size-based Simple Western system (recently developed by ProteinSimple). The method was able to accurately measure the absolute amounts of target proteins at picogram or sub-picogram levels per nanogram of cell lysates. The measurements were independent of the cell matrix or the cell lysis buffer and were not affected by different antibody affinities for their specific epitopes. We then applied this method to quantitate absolute levels of expression of protein kinase C (PKC) isoforms in LNCaP and U937 cells, two cell lines used extensively for probing the downstream biological responses to PKC targeted ligands. Our absolute quantitation confirmed the predominance of PKCδ in both cells, supporting the important functional role of this PKC isoform in these cell lines. The method described here provides an approach to accurately quantitate levels of protein expression and correlate protein level with function. In addition to enhanced accuracy relative to conventional Western analysis, it circumvents the distortions inherent in comparison with signal intensities from different antibodies with different affinities.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Anal Biochem

DOI

EISSN

1096-0309

Publication Date

November 1, 2013

Volume

442

Issue

1

Start / End Page

97 / 103

Location

United States

Related Subject Headings

  • Recombinant Proteins
  • Protein Kinase C
  • Isoenzymes
  • Immunoassay
  • Humans
  • Cell Line, Tumor
  • Blotting, Western
  • Biochemistry & Molecular Biology
  • Automation
  • 3401 Analytical chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chen, J.-Q., Heldman, M. R., Herrmann, M. A., Kedei, N., Woo, W., Blumberg, P. M., & Goldsmith, P. K. (2013). Absolute quantitation of endogenous proteins with precision and accuracy using a capillary Western system. Anal Biochem, 442(1), 97–103. https://doi.org/10.1016/j.ab.2013.07.022
Chen, Jin-Qiu, Madeleine R. Heldman, Michelle A. Herrmann, Noemi Kedei, Wonhee Woo, Peter M. Blumberg, and Paul K. Goldsmith. “Absolute quantitation of endogenous proteins with precision and accuracy using a capillary Western system.Anal Biochem 442, no. 1 (November 1, 2013): 97–103. https://doi.org/10.1016/j.ab.2013.07.022.
Chen J-Q, Heldman MR, Herrmann MA, Kedei N, Woo W, Blumberg PM, et al. Absolute quantitation of endogenous proteins with precision and accuracy using a capillary Western system. Anal Biochem. 2013 Nov 1;442(1):97–103.
Chen, Jin-Qiu, et al. “Absolute quantitation of endogenous proteins with precision and accuracy using a capillary Western system.Anal Biochem, vol. 442, no. 1, Nov. 2013, pp. 97–103. Pubmed, doi:10.1016/j.ab.2013.07.022.
Chen J-Q, Heldman MR, Herrmann MA, Kedei N, Woo W, Blumberg PM, Goldsmith PK. Absolute quantitation of endogenous proteins with precision and accuracy using a capillary Western system. Anal Biochem. 2013 Nov 1;442(1):97–103.
Journal cover image

Published In

Anal Biochem

DOI

EISSN

1096-0309

Publication Date

November 1, 2013

Volume

442

Issue

1

Start / End Page

97 / 103

Location

United States

Related Subject Headings

  • Recombinant Proteins
  • Protein Kinase C
  • Isoenzymes
  • Immunoassay
  • Humans
  • Cell Line, Tumor
  • Blotting, Western
  • Biochemistry & Molecular Biology
  • Automation
  • 3401 Analytical chemistry