December 2000

Iodophor and alcohol pledgets were compared with the Medi-Flex Prep Kit II for skin disinfection before venipuncture. Of 12,367 blood cultures collected, 6,362 were done with conventional pledgets and 6, 005 were done with Medi-Flex kits. Contamination occurred in 351 of 6,362 blood cultures (5.5%; range, 3.7 to 8.1%) with conventional pledgets versus 328 of 6,005 (5.5%; range, 3.5 to 7.5%) with Medi-Flex kits.

Duke Scholars

Published In

J Clin Microbiol

DOI

ISSN

0095-1137

Publication Date

December 2000

Volume

38

Issue

12

Start / End Page

4665 / 4667

Location

United States

Related Subject Headings

  • Skin
  • Reagent Kits, Diagnostic
  • Microbiology
  • Iodophors
  • Humans
  • Ethanol
  • Disinfection
  • Bacteria
  • Bacteremia
  • 3207 Medical microbiology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wilson, M. L., Weinstein, M. P., Mirrett, S., Reimer, L. G., Fernando, C., Meredith, F. T., & Reller, L. B. (2000). Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures. J Clin Microbiol, 38(12), 4665–4667. https://doi.org/10.1128/JCM.38.12.4665-4667.2000
Wilson, M. L., M. P. Weinstein, S. Mirrett, L. G. Reimer, C. Fernando, F. T. Meredith, and L. B. Reller. “Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures.J Clin Microbiol 38, no. 12 (December 2000): 4665–67. https://doi.org/10.1128/JCM.38.12.4665-4667.2000.
Wilson ML, Weinstein MP, Mirrett S, Reimer LG, Fernando C, Meredith FT, et al. Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures. J Clin Microbiol. 2000 Dec;38(12):4665–7.
Wilson, M. L., et al. “Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures.J Clin Microbiol, vol. 38, no. 12, Dec. 2000, pp. 4665–67. Pubmed, doi:10.1128/JCM.38.12.4665-4667.2000.
Wilson ML, Weinstein MP, Mirrett S, Reimer LG, Fernando C, Meredith FT, Reller LB. Comparison of iodophor and alcohol pledgets with the Medi-Flex blood culture prep kit II for preventing contamination of blood cultures. J Clin Microbiol. 2000 Dec;38(12):4665–4667.

Published In

J Clin Microbiol

DOI

ISSN

0095-1137

Publication Date

December 2000

Volume

38

Issue

12

Start / End Page

4665 / 4667

Location

United States

Related Subject Headings

  • Skin
  • Reagent Kits, Diagnostic
  • Microbiology
  • Iodophors
  • Humans
  • Ethanol
  • Disinfection
  • Bacteria
  • Bacteremia
  • 3207 Medical microbiology