Skip to main content
Journal cover image

A bismuth germanate gamma-ray spectrometer with a plastic anticoincidence shield

Publication ,  Journal Article
Wagenaar, DJ; Roberson, NR; Weller, HR; Tilley, DR
Published in: Nuclear Inst. and Methods in Physics Research, A
January 15, 1985

Response functions to photons in the energy range of 4.4-26.6 MeV have been obtained for a 7.6 × 7.6 cm BGO scintillator surrounded by a 5.1 cm thick well-type anticoincident shield. An AmBe source and various (p, γ) reactions provided the gamma-rays. The energy resolutions obtained varied from 8.4% (fwhm) at Eγ = 4.4 MeV to 6.6% at 21.0 MeV. The efficiency of the system has been determined by using the 12C(p, γ)13N reaction near Ep(Eγ) = 14.24 (15.07) MeV. In addition, the response function has been obtained for 18 MeV gamma-rays from the 40Ca(n, γ)41Ca reaction using 10 MeV neutrons produced via the 2H(d, n)3He reaction. © 1985.

Duke Scholars

Published In

Nuclear Inst. and Methods in Physics Research, A

DOI

ISSN

0168-9002

Publication Date

January 15, 1985

Volume

234

Issue

1

Start / End Page

109 / 115

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
  • 0201 Astronomical and Space Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wagenaar, D. J., Roberson, N. R., Weller, H. R., & Tilley, D. R. (1985). A bismuth germanate gamma-ray spectrometer with a plastic anticoincidence shield. Nuclear Inst. and Methods in Physics Research, A, 234(1), 109–115. https://doi.org/10.1016/0168-9002(85)90814-9
Wagenaar, D. J., N. R. Roberson, H. R. Weller, and D. R. Tilley. “A bismuth germanate gamma-ray spectrometer with a plastic anticoincidence shield.” Nuclear Inst. and Methods in Physics Research, A 234, no. 1 (January 15, 1985): 109–15. https://doi.org/10.1016/0168-9002(85)90814-9.
Wagenaar DJ, Roberson NR, Weller HR, Tilley DR. A bismuth germanate gamma-ray spectrometer with a plastic anticoincidence shield. Nuclear Inst and Methods in Physics Research, A. 1985 Jan 15;234(1):109–15.
Wagenaar, D. J., et al. “A bismuth germanate gamma-ray spectrometer with a plastic anticoincidence shield.” Nuclear Inst. and Methods in Physics Research, A, vol. 234, no. 1, Jan. 1985, pp. 109–15. Scopus, doi:10.1016/0168-9002(85)90814-9.
Wagenaar DJ, Roberson NR, Weller HR, Tilley DR. A bismuth germanate gamma-ray spectrometer with a plastic anticoincidence shield. Nuclear Inst and Methods in Physics Research, A. 1985 Jan 15;234(1):109–115.
Journal cover image

Published In

Nuclear Inst. and Methods in Physics Research, A

DOI

ISSN

0168-9002

Publication Date

January 15, 1985

Volume

234

Issue

1

Start / End Page

109 / 115

Related Subject Headings

  • Nuclear & Particles Physics
  • 5106 Nuclear and plasma physics
  • 0299 Other Physical Sciences
  • 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
  • 0201 Astronomical and Space Sciences