[Ultrasonographic study on primary hyperparathyroidism: evaluation of B-mode and color Doppler ultrasonography in localization]
Publication
, Journal Article
Zhang, JX; Li, JC; Cai, S
Published in: Zhonghua yi xue za zhi
October 1994
Seventy six patients with primary hyperparathyroidism were studied systematically by B-mode ultrasonography (BUS) and color Doppler flow imaging (CDFI). The sensitivity to the patients was 72%, specificity 92%, accuracy 87%, positive predictive value 69%, and negative predictive value 92%. The diagnostic efficiency was the highest in the parathyroid adenomas in normal position. By comparing the diagnostic efficiency of BUS with CDFI, we found that the sensitivity was significantly different (P
Duke Scholars
Published In
Zhonghua yi xue za zhi
ISSN
0376-2491
Publication Date
October 1994
Volume
74
Issue
10
Start / End Page
598 / 601, 645
Location
china
Related Subject Headings
- Oncology & Carcinogenesis
- General & Internal Medicine
- 1199 Other Medical and Health Sciences
- 1102 Cardiorespiratory Medicine and Haematology
Citation
APA
Chicago
ICMJE
MLA
NLM
Zhang, J. X., Li, J. C., & Cai, S. (1994). [Ultrasonographic study on primary hyperparathyroidism: evaluation of B-mode and color Doppler ultrasonography in localization]. Zhonghua Yi Xue Za Zhi, 74(10), 598-601,645.
Zhang, J. X., J. C. Li, and S. Cai. “[Ultrasonographic study on primary hyperparathyroidism: evaluation of B-mode and color Doppler ultrasonography in localization].” Zhonghua Yi Xue Za Zhi 74, no. 10 (October 1994): 598-601,645.
Zhang JX, Li JC, Cai S. [Ultrasonographic study on primary hyperparathyroidism: evaluation of B-mode and color Doppler ultrasonography in localization]. Zhonghua yi xue za zhi. 1994 Oct;74(10):598-601,645.
Zhang, J. X., et al. “[Ultrasonographic study on primary hyperparathyroidism: evaluation of B-mode and color Doppler ultrasonography in localization].” Zhonghua Yi Xue Za Zhi, vol. 74, no. 10, Oct. 1994, pp. 598-601,645.
Zhang JX, Li JC, Cai S. [Ultrasonographic study on primary hyperparathyroidism: evaluation of B-mode and color Doppler ultrasonography in localization]. Zhonghua yi xue za zhi. 1994 Oct;74(10):598-601,645.
Published In
Zhonghua yi xue za zhi
ISSN
0376-2491
Publication Date
October 1994
Volume
74
Issue
10
Start / End Page
598 / 601, 645
Location
china
Related Subject Headings
- Oncology & Carcinogenesis
- General & Internal Medicine
- 1199 Other Medical and Health Sciences
- 1102 Cardiorespiratory Medicine and Haematology