Skip to main content

Safety and efficacy of sonicated albumin microspheres in perfusion and vein graft patency assessments.

Publication ,  Journal Article
Ismail, S; Johnson, SH; Utsunomiya, H; Craig, D; Kisslo, JA; Smith, PK
Published in: Clin Cardiol
November 1991

This study was designed to identify a concentration of sonicated albumin microspheres that is safe, useful in determining graft patency, and provides an estimate of regional myocardial perfusion. The study included 8 patients between 50 and 72 years of age who were undergoing coronary artery bypass grafting. All patients were hemodynamically stable with left ventricular ejection fractions greater than or equal to 0.35. None had congestive heart failure or myocardial infarction within 4 months prior to the study. All had normal baseline neurologic and renal functions, and none had experienced allergic reactions to blood products or contrast dyes. A standard median sternotomy was performed for exposure of the heart at surgery, and saphenous veins were harvested and used for grafting. Intraoperative epicardial echocardiography (EE), always in the left ventricle short-axis at midpapillary level, was performed before and after grafting to determine regional myocardial wall motion. Sonicated albumin microspheres were prepared and injected into a single vein graft using an 18-gauge needle; 20 x 10(6), 100 x 10(6), and 200 x 10(6) microspheres were injected into the first graft sequentially. All other vein grafts were injected once with the dose that gave optimal contrast enhancement in the initial graft studied. In each patient, a minimum of 3 and maximum of 5 injections were performed, and graft perfusion was studied using EE. Graft flow, blood pressure, and electrocardiographic (ECG) measurements were continuously monitored, with a final EE performed after weaning the patient off cardiopulmonary bypass to assess wall motion. Preliminary results showed that no patient had adverse effects during or after the study and all remained hemodynamically stable.(ABSTRACT TRUNCATED AT 250 WORDS)

Duke Scholars

Published In

Clin Cardiol

DOI

ISSN

0160-9289

Publication Date

November 1991

Volume

14

Issue

11 Suppl 5

Start / End Page

V29 / V32

Location

United States

Related Subject Headings

  • Vascular Patency
  • Monitoring, Intraoperative
  • Middle Aged
  • Microspheres
  • Male
  • Image Enhancement
  • Humans
  • Female
  • Echocardiography
  • Coronary Artery Bypass
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ismail, S., Johnson, S. H., Utsunomiya, H., Craig, D., Kisslo, J. A., & Smith, P. K. (1991). Safety and efficacy of sonicated albumin microspheres in perfusion and vein graft patency assessments. Clin Cardiol, 14(11 Suppl 5), V29–V32. https://doi.org/10.1002/clc.4960141707
Ismail, S., S. H. Johnson, H. Utsunomiya, D. Craig, J. A. Kisslo, and P. K. Smith. “Safety and efficacy of sonicated albumin microspheres in perfusion and vein graft patency assessments.Clin Cardiol 14, no. 11 Suppl 5 (November 1991): V29–32. https://doi.org/10.1002/clc.4960141707.
Ismail S, Johnson SH, Utsunomiya H, Craig D, Kisslo JA, Smith PK. Safety and efficacy of sonicated albumin microspheres in perfusion and vein graft patency assessments. Clin Cardiol. 1991 Nov;14(11 Suppl 5):V29–32.
Ismail, S., et al. “Safety and efficacy of sonicated albumin microspheres in perfusion and vein graft patency assessments.Clin Cardiol, vol. 14, no. 11 Suppl 5, Nov. 1991, pp. V29–32. Pubmed, doi:10.1002/clc.4960141707.
Ismail S, Johnson SH, Utsunomiya H, Craig D, Kisslo JA, Smith PK. Safety and efficacy of sonicated albumin microspheres in perfusion and vein graft patency assessments. Clin Cardiol. 1991 Nov;14(11 Suppl 5):V29–V32.

Published In

Clin Cardiol

DOI

ISSN

0160-9289

Publication Date

November 1991

Volume

14

Issue

11 Suppl 5

Start / End Page

V29 / V32

Location

United States

Related Subject Headings

  • Vascular Patency
  • Monitoring, Intraoperative
  • Middle Aged
  • Microspheres
  • Male
  • Image Enhancement
  • Humans
  • Female
  • Echocardiography
  • Coronary Artery Bypass