In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps.

Publication ,  Journal Article
Farrar, DJ; Litwak, P; Lawson, JH; Ward, RS; White, KA; Robinson, AJ; Rodvien, R; Hill, JD
Published in: J Thorac Cardiovasc Surg
February 1988

To reduce the risk of thromboembolic complications in prosthetic blood pumps, we have developed a new segmented polyurethane elastomer. This material is unique because its mechanical properties for long-term durability and surface properties for biocompatibility have been separated and developed in two distinct materials. Improved thromboresistance is then obtained by a 1% concentration of a new polymeric surface-modifying additive blended with the base polyurethane before fabrication of the blood pump. To evaluate this material in vivo, we performed 10 implants, in calves, of the Pierce-Donachy prosthetic ventricle with blood-pumping sacs and cannulas fabricated from the new surface-modifying additive copolymer blend (Thoratec's BPS-215M). In four control implants the blood sacs and cannulas were fabricated from Ethicon's Biomer segmented polyurethane, which is the present clinical standard for most artificial hearts and circulatory support devices. The blood pumps were connected from the apex of the left ventricle to the descending aorta in male Holstein calves weighing 82 to 108 kg and were driven pneumatically in the full-to-empty mode with flows averaging 5 to 6 L/min. Each calf was medicated with aspirin and dipyridamole throughout the study period and was electively put to death after 4 weeks for evaluation of explanted blood sacs and for examination of the kidneys for infarction. All 10 explanted blood sacs made with the surface-modifying additive copolymer blend were shiny and completely free of thrombus. Three of the four explanted Biomer blood sacs showed visible red thrombus, and all four showed small areas of white thrombus. The average surface area of the Biomer blood sacs covered with thrombus was 45 +/- 32 mm2. Use of a semiquantitative scale to assess renal infarction demonstrated that nine of 10 animals with a surface-modifying additive copolymer blend blood sac had infarction less severe than the mean infarct score of the animals with a Biomer sac. The surface-modifying additive copolymer blend has excellent mechanical and physical properties necessary for use in artificial heart blood pumps. From these experiments, we conclude that the surface-modified polyurethane blend is superior to Biomer polyurethane in blood compatibility and in freedom from thromboembolic risk. This material is now approved by the Food and Drug Administration for investigational device exemption studies in the Pierce-Donachy prosthetic ventricle.

Duke Scholars

Published In

J Thorac Cardiovasc Surg

ISSN

0022-5223

Publication Date

February 1988

Volume

95

Issue

2

Start / End Page

191 / 200

Location

United States

Related Subject Headings

  • Time Factors
  • Thromboembolism
  • Surface Properties
  • Structure-Activity Relationship
  • Respiratory System
  • Polyurethanes
  • Platelet Count
  • Materials Testing
  • Male
  • Kidney
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Farrar, D. J., Litwak, P., Lawson, J. H., Ward, R. S., White, K. A., Robinson, A. J., … Hill, J. D. (1988). In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps. J Thorac Cardiovasc Surg, 95(2), 191–200.
Farrar, D. J., P. Litwak, J. H. Lawson, R. S. Ward, K. A. White, A. J. Robinson, R. Rodvien, and J. D. Hill. “In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps.J Thorac Cardiovasc Surg 95, no. 2 (February 1988): 191–200.
Farrar DJ, Litwak P, Lawson JH, Ward RS, White KA, Robinson AJ, et al. In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps. J Thorac Cardiovasc Surg. 1988 Feb;95(2):191–200.
Farrar, D. J., et al. “In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps.J Thorac Cardiovasc Surg, vol. 95, no. 2, Feb. 1988, pp. 191–200.
Farrar DJ, Litwak P, Lawson JH, Ward RS, White KA, Robinson AJ, Rodvien R, Hill JD. In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps. J Thorac Cardiovasc Surg. 1988 Feb;95(2):191–200.
Journal cover image

Published In

J Thorac Cardiovasc Surg

ISSN

0022-5223

Publication Date

February 1988

Volume

95

Issue

2

Start / End Page

191 / 200

Location

United States

Related Subject Headings

  • Time Factors
  • Thromboembolism
  • Surface Properties
  • Structure-Activity Relationship
  • Respiratory System
  • Polyurethanes
  • Platelet Count
  • Materials Testing
  • Male
  • Kidney