Skip to main content
Journal cover image

Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI.

Publication ,  Journal Article
Fischer, MC; Spector, ZZ; Ishii, M; Yu, J; Emami, K; Itkin, M; Rizi, R
Published in: Magn Reson Med
October 2004

Magnetic resonance imaging (MRI) with hyperpolarized 3-helium gas (HP 3He) offers the possibility of studying functional lung parameters such as the alveolar oxygen concentration and oxygen depletion rate. Until now, a double-acquisition technique has been utilized to extract these parameters. A complicated single-acquisition technique was previously developed to avoid the necessity of performing two identical breathing maneuvers. The results obtained with this technique were significantly less accurate than the results obtained with the double-acquisition method. In this work, a novel, easily implemented single-acquisition sequence is presented that provides results comparable to those obtained with the established double-acquisition method. This method is demonstrated in a phantom and a pig model on a 1.5 T scanner using a 2D fast low-angle shot (FLASH) gradient-echo sequence. Numerical simulations of the time evolution of the oxygen concentration were performed. Simulation results are presented to support the experimental data. Various parameter regimes were experimentally and numerically investigated.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

October 2004

Volume

52

Issue

4

Start / End Page

766 / 773

Location

United States

Related Subject Headings

  • Swine
  • Phantoms, Imaging
  • Partial Pressure
  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Lung
  • Isotopes
  • Image Processing, Computer-Assisted
  • Helium
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Fischer, M. C., Spector, Z. Z., Ishii, M., Yu, J., Emami, K., Itkin, M., & Rizi, R. (2004). Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI. Magn Reson Med, 52(4), 766–773. https://doi.org/10.1002/mrm.20239
Fischer, M. C., Z. Z. Spector, M. Ishii, J. Yu, K. Emami, M. Itkin, and R. Rizi. “Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI.Magn Reson Med 52, no. 4 (October 2004): 766–73. https://doi.org/10.1002/mrm.20239.
Fischer MC, Spector ZZ, Ishii M, Yu J, Emami K, Itkin M, et al. Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI. Magn Reson Med. 2004 Oct;52(4):766–73.
Fischer, M. C., et al. “Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI.Magn Reson Med, vol. 52, no. 4, Oct. 2004, pp. 766–73. Pubmed, doi:10.1002/mrm.20239.
Fischer MC, Spector ZZ, Ishii M, Yu J, Emami K, Itkin M, Rizi R. Single-acquisition sequence for the measurement of oxygen partial pressure by hyperpolarized gas MRI. Magn Reson Med. 2004 Oct;52(4):766–773.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

October 2004

Volume

52

Issue

4

Start / End Page

766 / 773

Location

United States

Related Subject Headings

  • Swine
  • Phantoms, Imaging
  • Partial Pressure
  • Oxygen
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Lung
  • Isotopes
  • Image Processing, Computer-Assisted
  • Helium