This paper presents the benchmark problem definition for seismically excited base-isolated buildings. The objective of this benchmark study is to provide a well-defined base-isolated building with a broad set of carefully chosen parameter sets, performance measures and guidelines to the participants, so that they can evaluate their control algorithms. The control algorithms may be passive, active or semi-active. The benchmark structure considered is an eight-storey base-isolated building similar to existing buildings in Los Angeles, California. The base isolation system includes both linear and nonlinear bearings and control devices. The superstructure is considered to be a linear elastic system with lateral - torsional behavior. A new nonlinear dynamic analysis program has been developed and made available to facilitate direct comparison of results of different control algorithms. Copyright © 2005 John Wiley and Sons, Ltd.

Full Text

Duke Authors

Cited Authors

  • Narasimhan, S; Nagarajaiah, S; Johnson, EA; Gavin, HP

Published Date

  • 2006

Published In

  • Structural Control and Health Monitoring

Volume / Issue

  • 13 / 2-3

Start / End Page

  • 573 - 588

Digital Object Identifier (DOI)

  • 10.1002/stc.99