Skip to main content
Journal cover image

Group index of the human cornea at 1.3-microm wavelength obtained in vitro by optical coherence domain reflectometry.

Publication ,  Journal Article
Lin, RC; Shure, MA; Rollins, AM; Izatt, JA; Huang, D
Published in: Optics letters
January 2004

The group index of the cornea, rather than the phase refractive index, is required for thickness calculations with optical coherence tomography. Recent advances with high-speed optical coherence tomography at 1.3 microm make index measurement at this wavelength of great interest. Group indices of three human corneas from an eye bank were measured in vitro with optical coherence domain reflectometry. Measurements were made in a calibrated cuvette filled with a preservation medium to maintain proper corneal hydration. Group indices were calculated from the optical path lengths measured. The corneal group index was 1.389 +/- 0.004 (average +/- standard deviation). The average group index of a balanced salt solution, an approximation to aqueous humor, was 1.343 +/- 0.001.

Published In

Optics letters

DOI

EISSN

1539-4794

ISSN

0146-9592

Publication Date

January 2004

Volume

29

Issue

1

Start / End Page

83 / 85

Related Subject Headings

  • Tomography, Optical Coherence
  • Scattering, Radiation
  • Organ Preservation Solutions
  • Optics
  • In Vitro Techniques
  • Humans
  • Gentamicins
  • Dextrans
  • Culture Media, Serum-Free
  • Cornea
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Lin, R. C., Shure, M. A., Rollins, A. M., Izatt, J. A., & Huang, D. (2004). Group index of the human cornea at 1.3-microm wavelength obtained in vitro by optical coherence domain reflectometry. Optics Letters, 29(1), 83–85. https://doi.org/10.1364/ol.29.000083
Lin, Roger C., Mark A. Shure, Andrew M. Rollins, Joseph A. Izatt, and David Huang. “Group index of the human cornea at 1.3-microm wavelength obtained in vitro by optical coherence domain reflectometry.Optics Letters 29, no. 1 (January 2004): 83–85. https://doi.org/10.1364/ol.29.000083.
Lin RC, Shure MA, Rollins AM, Izatt JA, Huang D. Group index of the human cornea at 1.3-microm wavelength obtained in vitro by optical coherence domain reflectometry. Optics letters. 2004 Jan;29(1):83–5.
Lin, Roger C., et al. “Group index of the human cornea at 1.3-microm wavelength obtained in vitro by optical coherence domain reflectometry.Optics Letters, vol. 29, no. 1, Jan. 2004, pp. 83–85. Epmc, doi:10.1364/ol.29.000083.
Lin RC, Shure MA, Rollins AM, Izatt JA, Huang D. Group index of the human cornea at 1.3-microm wavelength obtained in vitro by optical coherence domain reflectometry. Optics letters. 2004 Jan;29(1):83–85.
Journal cover image

Published In

Optics letters

DOI

EISSN

1539-4794

ISSN

0146-9592

Publication Date

January 2004

Volume

29

Issue

1

Start / End Page

83 / 85

Related Subject Headings

  • Tomography, Optical Coherence
  • Scattering, Radiation
  • Organ Preservation Solutions
  • Optics
  • In Vitro Techniques
  • Humans
  • Gentamicins
  • Dextrans
  • Culture Media, Serum-Free
  • Cornea