Exposure time dependence of image quality in high-speed retinal in vivo Fourier-domain OCT

Publication ,  Journal Article
Zawadzki, RJ; Bower, BA; Zhao, M; Sarunic, M; Laut, S; Werner, JS; Izatt, JA
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
July 21, 2005

We built a Fourier domain optical coherence tomography (FD-OCT) system using a line scan CCD camera that allows real time data display and acquisition. This instrument is able to produce 2D B-scans as well as 3D data sets with human subjects in vivo in clinical settings. In this paper we analyze the influence of varying exposure times of the CCD detector on image quality. Sensitivity values derived from theoretical predictions have been compared with measurements (obtained with mirrors and neutral density filters placed in both interferometer arms). The results of these experiments, discussion about differences between sensitivity values, potential sources of discrepancies, and recommendations for optimal exposure times will be described in this paper. A short discussion of observed artifacts as well as possible ways to remove them is presented. The influence of relative retinal position with respect to reference mirror position will also be described.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

July 21, 2005

Volume

5688

Start / End Page

45 / 52
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zawadzki, R. J., Bower, B. A., Zhao, M., Sarunic, M., Laut, S., Werner, J. S., & Izatt, J. A. (2005). Exposure time dependence of image quality in high-speed retinal in vivo Fourier-domain OCT. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 5688, 45–52. https://doi.org/10.1117/12.591660
Zawadzki, R. J., B. A. Bower, M. Zhao, M. Sarunic, S. Laut, J. S. Werner, and J. A. Izatt. “Exposure time dependence of image quality in high-speed retinal in vivo Fourier-domain OCT.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 5688 (July 21, 2005): 45–52. https://doi.org/10.1117/12.591660.
Zawadzki RJ, Bower BA, Zhao M, Sarunic M, Laut S, Werner JS, et al. Exposure time dependence of image quality in high-speed retinal in vivo Fourier-domain OCT. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2005 Jul 21;5688:45–52.
Zawadzki, R. J., et al. “Exposure time dependence of image quality in high-speed retinal in vivo Fourier-domain OCT.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 5688, July 2005, pp. 45–52. Scopus, doi:10.1117/12.591660.
Zawadzki RJ, Bower BA, Zhao M, Sarunic M, Laut S, Werner JS, Izatt JA. Exposure time dependence of image quality in high-speed retinal in vivo Fourier-domain OCT. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2005 Jul 21;5688:45–52.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

July 21, 2005

Volume

5688

Start / End Page

45 / 52