Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat's principle.

Publication ,  Journal Article
Westphal, V; Rollins, A; Radhakrishnan, S; Izatt, J
Published in: Optics express
May 2002

We describe a methodology for quantitative image correction in OCT which includes procedures for correction of nonlinear axial scanning and non-telecentric scan patterns, as well as a novel approach for refraction correction in layered media based on Fermat's principle. The residual spatial error obtained in layered media with a fan-beam hand-held probe was reduced from several hundred micrometers to near the diffraction and coherence-length limits.

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Optics express

DOI

EISSN

1094-4087

ISSN

1094-4087

Publication Date

May 2002

Volume

10

Issue

9

Start / End Page

397 / 404

Related Subject Headings

  • Optics
  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
  • 1005 Communications Technologies
  • 0906 Electrical and Electronic Engineering
  • 0205 Optical Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Westphal, V., Rollins, A., Radhakrishnan, S., & Izatt, J. (2002). Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat's principle. Optics Express, 10(9), 397–404. https://doi.org/10.1364/oe.10.000397
Westphal, Volker, Andrew Rollins, Sunita Radhakrishnan, and Joseph Izatt. “Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat's principle.Optics Express 10, no. 9 (May 2002): 397–404. https://doi.org/10.1364/oe.10.000397.
Westphal V, Rollins A, Radhakrishnan S, Izatt J. Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat's principle. Optics express. 2002 May;10(9):397–404.
Westphal, Volker, et al. “Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat's principle.Optics Express, vol. 10, no. 9, May 2002, pp. 397–404. Epmc, doi:10.1364/oe.10.000397.
Westphal V, Rollins A, Radhakrishnan S, Izatt J. Correction of geometric and refractive image distortions in optical coherence tomography applying Fermat's principle. Optics express. 2002 May;10(9):397–404.
Journal cover image

Published In

Optics express

DOI

EISSN

1094-4087

ISSN

1094-4087

Publication Date

May 2002

Volume

10

Issue

9

Start / End Page

397 / 404

Related Subject Headings

  • Optics
  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
  • 1005 Communications Technologies
  • 0906 Electrical and Electronic Engineering
  • 0205 Optical Physics