Skip to main content

Improved real time volumetric ultrasonic imaging system

Publication ,  Journal Article
Pavy, HG; W. Smith, S; von Ramm, OT
Published in: Proceedings of SPIE - The International Society for Optical Engineering
January 1, 1991

A real time volumetric ultrasonic imaging system has been improved through the use of parallel processing in two dimensions. The imaging system uses pulse-echo phased array principles to steer a two-dimensional transducer array in a pyramidal scan format. The transducer array consists of 96 transmit elements and 32 receive elements, and operates a center frequency of 2.5 MHz. Parallel processing allows reception of 16 unique view directions distributed over a small pyramidal volume during receive. Information from the 16 directions is obtained simultaneously after the transmission of an ultrasonic pulse. Images consisting of 4096 lines are produced at a rate of over 15 frames/second. The images are analogous to those produced by an optical camera or the human eye and supply more information than conventional sonograms. Echo data for the scanned volume is presented as projection images with depth perspective, stereoscopic pairs, multiple tomographic images, or C-scans. Potential medical applications include improved anatomic visualization, tumor localization, and better assessment of cardiac function.

Duke Scholars

Published In

Proceedings of SPIE - The International Society for Optical Engineering

ISSN

0277-786X

Publication Date

January 1, 1991

Volume

1443

Start / End Page

54 / 61
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pavy, H. G., W. Smith, S., & von Ramm, O. T. (1991). Improved real time volumetric ultrasonic imaging system. Proceedings of SPIE - The International Society for Optical Engineering, 1443, 54–61.
Pavy, H. G., S. W. Smith, and O. T. von Ramm. “Improved real time volumetric ultrasonic imaging system.” Proceedings of SPIE - The International Society for Optical Engineering 1443 (January 1, 1991): 54–61.
Pavy HG, W. Smith S, von Ramm OT. Improved real time volumetric ultrasonic imaging system. Proceedings of SPIE - The International Society for Optical Engineering. 1991 Jan 1;1443:54–61.
Pavy, H. G., et al. “Improved real time volumetric ultrasonic imaging system.” Proceedings of SPIE - The International Society for Optical Engineering, vol. 1443, Jan. 1991, pp. 54–61.
Pavy HG, W. Smith S, von Ramm OT. Improved real time volumetric ultrasonic imaging system. Proceedings of SPIE - The International Society for Optical Engineering. 1991 Jan 1;1443:54–61.

Published In

Proceedings of SPIE - The International Society for Optical Engineering

ISSN

0277-786X

Publication Date

January 1, 1991

Volume

1443

Start / End Page

54 / 61