Skip to main content
Journal cover image

ANTIBODY-BASED FIBEROPTICS BIOSENSOR FOR THE CARCINOGEN BENZO(A)PYRENE.

Publication ,  Journal Article
Vo-Dinh, T; Tromberg, BJ; Griffin, GD; Ambrose, KR; Sepaniak, MJ; Gardenhire, EM
Published in: Applied Spectroscopy
January 1, 1987

A new antibody-based fiberoptics biosensor was used to detect the important carcinogen benzo(a)pyrene (BaP). The fiberoptics sensor utilizes anti-BaP antibodies covalently bound to its tip. A helium cadmium laser was used as the excitation source to induce fluorescence from BaP conjugated to the bound anti-BaP antibodies. The fiberoptics device can detect 1 femtomole of BaP in a 5- mu L sample drop.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Applied Spectroscopy

DOI

ISSN

0003-7028

Publication Date

January 1, 1987

Volume

41

Issue

5

Start / End Page

735 / 738

Related Subject Headings

  • Analytical Chemistry
  • 0913 Mechanical Engineering
  • 0306 Physical Chemistry (incl. Structural)
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Vo-Dinh, T., Tromberg, B. J., Griffin, G. D., Ambrose, K. R., Sepaniak, M. J., & Gardenhire, E. M. (1987). ANTIBODY-BASED FIBEROPTICS BIOSENSOR FOR THE CARCINOGEN BENZO(A)PYRENE. Applied Spectroscopy, 41(5), 735–738. https://doi.org/10.1366/0003702874448076
Vo-Dinh, T., B. J. Tromberg, G. D. Griffin, K. R. Ambrose, M. J. Sepaniak, and E. M. Gardenhire. “ANTIBODY-BASED FIBEROPTICS BIOSENSOR FOR THE CARCINOGEN BENZO(A)PYRENE.Applied Spectroscopy 41, no. 5 (January 1, 1987): 735–38. https://doi.org/10.1366/0003702874448076.
Vo-Dinh T, Tromberg BJ, Griffin GD, Ambrose KR, Sepaniak MJ, Gardenhire EM. ANTIBODY-BASED FIBEROPTICS BIOSENSOR FOR THE CARCINOGEN BENZO(A)PYRENE. Applied Spectroscopy. 1987 Jan 1;41(5):735–8.
Vo-Dinh, T., et al. “ANTIBODY-BASED FIBEROPTICS BIOSENSOR FOR THE CARCINOGEN BENZO(A)PYRENE.Applied Spectroscopy, vol. 41, no. 5, Jan. 1987, pp. 735–38. Scopus, doi:10.1366/0003702874448076.
Vo-Dinh T, Tromberg BJ, Griffin GD, Ambrose KR, Sepaniak MJ, Gardenhire EM. ANTIBODY-BASED FIBEROPTICS BIOSENSOR FOR THE CARCINOGEN BENZO(A)PYRENE. Applied Spectroscopy. 1987 Jan 1;41(5):735–738.
Journal cover image

Published In

Applied Spectroscopy

DOI

ISSN

0003-7028

Publication Date

January 1, 1987

Volume

41

Issue

5

Start / End Page

735 / 738

Related Subject Headings

  • Analytical Chemistry
  • 0913 Mechanical Engineering
  • 0306 Physical Chemistry (incl. Structural)
  • 0301 Analytical Chemistry